Model | KV-CA02*1 |
General specifications | Power voltage | System configuration using an expansion unit for KV-5000/3000 Series: 24 VDC (±10%)*2System configuration using an expansion unit only for KV-8000/7000 Series: 24 VDC (-15%/+20%)*2 |
Operating ambient temperature | System configuration using an expansion unit for KV-5000/3000 Series: 0 to +50°C 32 to 122°F(no freezing)*3*4System configuration using an expansion unit only for KV-8000/7000 Series: 0 to +55°C 32 to 131°F(no freezing)*3*4 |
Operating ambient humidity | System configuration using an expansion unit for KV-5000/3000 Series: 10 to 95% RH(no condensation)*3System configuration using an expansion unit only for KV-8000/7000 Series: 5 to 95% RH(no condensation)*3 |
Storage ambient temperature | System configuration using an expansion unit for KV-5000/3000 Series: -20 to +70°C -4 to +158°F*3System configuration using an expansion unit only for KV-8000/7000 Series: -25 to +75°C -13 to +167°F*3 |
Storage relative humidity | System configuration using an expansion unit for KV-5000/3000 Series: 10 to 95% RH(no condensation)*3System configuration using an expansion unit only for KV-8000/7000 Series: 5 to 95% RH(no condensation)*3 |
Operating environment | No dust or corrosive gas |
Operating altitude | 2000 m 6561.7′ or less |
Noise immunity | 1500 Vp-p or morePulse duration: 1 μs, 50 ns (based on noise simulator)IEC standard-compliant (IEC 61000-4-2/3/4/6) |
Withstand voltage | 1500 VAC for one minute (between the power terminals and the I/O terminals, and between the external terminals and the case) |
Insulation resistance | 50 MΩ or more (between the power terminals and the I/O terminals and between the external terminals and the case, with 500 VDC megohmmeter) |
Vibration resistance | Intermittent vibration | Frequency 5 to 9 Hz | Half amplitude 3.5 mm 0.14″*5 |
Frequency 9 to 150 Hz | Acceleration 9.8 m/s2 32.2’/s2*5 |
Continuous vibration | Frequency 5 to 9 Hz | Half amplitude 1.75 mm 0.07″*5 |
Frequency 9 to 150 Hz | Acceleration 4.9 m/s2 16.1’/s2*5 |
Shock resistance | Acceleration: 150 m/s2 492.1’/s2, Application time: 11 ms, 2 times in each of the X, Y, and Z directions |
Pollution degree | 2 |
Performance specifications | Connectable CPU unit | KV-8000A |
Max. number of connectable units | 4 |
Number of ports | 2 |
Supported camera models | KV-CA1H (Compact standard camera)KV-CA1W (Wide-field high-resolution camera) |
Cable length | 5/10/20 m 16.4’/32.8’/65.6′*6 |
Recording time | Approx. 3 minutes*7 |
Internal current consumption | 260 mA or less*8 |
Weight | Approx. 190 g |
*1 for use with KV-8000 Series*2 Supplied via the CPU unit or expansion unit.*3 Guaranteed range in which the system can be used.*4 Specified according to the temperature in the control panel on the lower side of the unit.*5 Compliant with JIS B 3502 IEC 61131-2, Scan times: 10 times in each of the X, Y, and Z directions (for 100 min.)*6 Lengths of the KV-C5/C10/C20 camera cables.*7 Record time for one KV-CA1H with the following configuration of settings (initial value). The actual recording time varies depending on the number of devices, the frame rate, and the image quality settings. Frame rate: 30 fps/Quality: 3In addition, the recorded video is cleared when the power is turned off.*8 Internal current consumption for the KV-CA02 only. Connecting a camera adds the internal current consumption of the connected camera. |