Keyence FI-CF3

Pipe attachment NPT3/4 for FI-C40F
SKU: FI-CF3
Hãng sản xuất: Keyence
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng từ: CO/CQ, hóa đơn VAT

Báo giá
Mã: FI-CF3 Danh mục:

Model

FI-CF3

Type

Pipe type

Main unit

FI-C40F

Detection principle

Refractive index (surface light source)

Rated concentration range

Brix: 0–40% (nD: 1.32500–1.41000)

Display method

Status indicator light

Display range

Brix: 0–50%

Supported fluids

Non-corrosive aqueous solutions (such as water-soluble coolants, mold release agents, etc.)*1

Supported fluid temperature

0–70°C 32–158°F (no freezing)

Connection diameter

NPT3/4

Rated pressure range

1.0 MPa or less

Pressure resistance

2.0 MPa

Display resolution

Brix: 0.01/0.1% (default value: 0.1)
(nD: 0.00001)

Response time

1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s

Measurement accuracy

Brix: ±0.2%*2*3 (nD: ±0.0003)

Concentration unit

Brix nD*4

Temperature measurement accuracy

±1.0°C 1.8°F*2

Power supply

Current consumption

25 mA or less

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient temperature

–10 to +60°C 14 to +140°F (no freezing)

Relative humidity

35–85% RH (no condensation)

Vibration resistance

10–500 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions

Shock resistance

100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z directions

Material

Liquid end materials

Body: SCS16A; Gasket: FKM

Other materials

Body: SUS304; PPS indicator light: PPSU / TPU / PBT
Cable: PVC

Weight

Approx. 790 g 27.87 oz

*1 Use water as the solvent, and use materials that are soluble in water. If the particles are not water soluble, such as with slurry, the refractive index may not change.
*2 This is the guaranteed value from verification performed at KEYENCE inspection facilities. Measurement error may occur depending on the type, condition and temperature of the fluid used by the customer, as well as other factors.
*3 This is the value obtained when sucrose solution is used in a constant 20°C 68°F environment, and absolute error and repeatability is taken into account.
*4 When using solutions other than sucrose solutions, concentration can be adjusted via span adjustment.

Thông tin bổ sung

Thương hiệu
Thời gian bảo hành

1 Năm

Series
Yêu cầu tư vấn0342 678 887(Call/Zalo)

Khu vực Miền Nam

Call: 0345 177 768 / Chat Zalo zalo

Khu vực Miền Bắc

Call: 0384 988 968 / Chat Zalo zalo

Khu vực Miền Trung

Call: 0374 687 899/ Chat Zalo zalo

Dịch vụ kỹ thuật/Bảo hành

Call: 0348 957 778/ Chat Zalo zalo

Email liên hệ

dich-vu-sua-chua-bien-tan-thiet-bi-tu-dong-hoa