Model | FI-T100 | |||
Supported pipe diameter | 2 1/2″, 3″, 3 1/2″, 4″(65 A, 80 A, 90 A, 100 A)ø70–126 ø2.76″–4.96″ | |||
Supported pipe materials | Metal piping | |||
Supported temperature range | −20 to +180°C –4 to +356°F*1 | |||
Display method | Organic EL, status indicator light | |||
Display resolution | 0.1°C 32.18°F | |||
Response time | 5 s (50% response), 15 s (90% response)*2 | |||
Display amplifier averaging time | 0.1 s / 10.0 s / 20.0 s / 30.0 s / 60.0 s / 120.0 s / 300.0 s | |||
Measurement accuracy | ±0.5°C ±0.9°F (pipe temperature −20 to +80°C –4 to 176°F) (ambient temperature of 25°C 77°F)*2*3±1.0°C ±1.8°F (pipe temperature 80–180°C 176–356°F) (ambient temperature of 25°C 77°F)*2*3 | |||
Hysteresis | Variable | |||
Measurement principle | Pt100 4-wire type | |||
Power I/O connector | M8 4-pin connector | |||
Power supply | Current consumption | 20 mA or less (excluding load current)*4 | ||
When used standalone | I/O (switchable) | Output (Ch1/Ch2) | Control output: switching NPN/PNP settingOpen collector output: 30 VDC or less, maximum 100 mA/ch or less, residual voltage 2.5 V or less*5 | |
Analog output (Ch2) | 4–20 mA / 0–20 mA (switchable), load resistance 260 Ω or less*5 | |||
Power voltage | 20–30 VDC, ripple (P-P) 10% included; Class2/LPS*5 | |||
Protection circuit | Protection against reverse power connection, power supply surges, output short circuits, and output surges*5 | |||
Network compatibility | IO-Link*6*5 | |||
Environmental resistance | Enclosure rating | IP65/IP67 (IEC60529) | ||
Ambient temperature | –10 to +60°C -14 to +140°F (no freezing) | |||
Relative humidity | 35–85% RH (no condensation) | |||
Vibration resistance | 10–500 Hz; power spectral density: 0.816 G2/Hz; X, Y and Z directions | |||
Shock resistance | 100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z directions | |||
Material | Display amplifier | PBT / PAR / POM / SUS303 | ||
Sensor head | Head: PPS / SUS303 / Sn; Pipe clamp unit: SUS304; Cable: fluororesin | |||
Display amplifier mounting bracket | SUS304 | |||
Weight | Approx. 100 g 3.53 oz | |||
*1 When pipe temperature is 100°C 212°F or more, the display amplifier cannot be mounted on the pipe clamp unit. Install the amplifier so it is insulated from the heat from the pipe.*2 This is the guaranteed value from verification performed at KEYENCE inspection facilities. Measurement error may occur depending on the type and condition of the customer’s pipes and fluid, the ambient temperature and other factors.*3 This is the value for a constant 25°C 77°F environment, taking into account absolute error and repeatability.*4 During standalone use, 220 mA or less including load.*5 When connecting to a FD-H Series/FI-1000 model, please follow the specifications of the display unit.*6 Supports IO-Link specification v.1.1/COM2 (38.4 kbps). Setting files can be downloaded from the KEYENCE website (www.keyence.com).IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO). |
Cảm biến nhiệt độ Keyence FI-T100
Temperature Sensors 65A/80A/90A/100A
SKU: FI-T100
Hãng sản xuất: Keyence
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng từ: CO/CQ, hóa đơn VAT
Thông tin bổ sung
Thương hiệu | |
---|---|
Thời gian bảo hành | 1 Năm |
Series | |
Yêu cầu tư vấn | 0983 995 440(Call/Zalo) |
Có thể bạn thích…
Khu vực Miền Nam
Khu vực Miền Bắc
Khu vực Miền Trung
Dịch vụ kỹ thuật/Bảo hành
Email liên hệ
Dịch vụ cung ứng sản phẩm
Vì sản phẩm đa dạng, nếu Quý khách chưa tìm được. Vui lòng liên hệ để được hỗ trợ.
Tư vấn lựa chọn hoặc chuyển đổi
Nhập khẩu thiết bị theo yêu cầu