Model | KV-XLE02 | |||
Type | Ethernet unit | |||
Connection interface | RJ-45 8-pole modular connector × 2 ports | |||
Transmission specifications | Transmission rate | 10BASE-T: 10 Mbps, 100BASE-TX: 100 Mbps, 1000BASE-T: 1000 Mbps *1 | ||
Transmission media | 10BASE-T: Category 3 or higher UTP or STP (STP is recommended) 100BASE-TX: Category 5 or higher UTP or STP (STP is recommended) 1000BASE-T: Category 5e or higher UTP or STP (double-shielded STP is recommended) *2 | |||
Max. cable length | 10BASE-T: 100 m 328.1′ 100BASE-TX: 100 m 328.1′ 1000BASE-T: 100 m 328.1′ *3 | |||
Max. number of connectable hubs | 10BASE-T: 4 100BASE-TX: 2 1000BASE-T: 1 *4 | |||
Refresh | Automatic refresh, direct refresh, inter-unit synchronization refresh | |||
Ethernet functions | KV socket communication, PLC link, PROTOCOL STUDIO, FTP server/client, KV sensor network, Modbus server*5, MC protocol/SLMP*6, etc. | |||
Industrial networks | EtherNet/IP™, PROFINET, EtherCAT®,*7 CC-Link IE Field*8*9 | |||
Ethernet function execution methods | Ladder program, unit program (flow) | |||
Unit program capacity | 3 MB (Max. number of blocks: Approx. 20000) | |||
flow | Max. number of flows | 256 | ||
Number of simultaneous activities | Unlimited | |||
Flow | Internal data Memory | 524288 words | ||
PROTOCOL STUDIO | Transmission method | Cyclic communication: Tx + Rx, Tx only, Rx only. Event communication: Tx + Rx, Tx only, Rx only, Tx + Continuous Rx | ||
Max. number of connected devices | 16 | |||
Max. number of communication commands | 160/320*10 | |||
Maximum number of total frames | Rx: 160/320*10 × 16 Tx: 160/320*10 × 1 | |||
Max. number of compared received frames | 16 per command | |||
Maximum number of block elements | 96 per frame | |||
Transmission data length | Standard: 1 to 2048 bytes per frame, Extended: 1 to 16384 bytes per frame | |||
Reception data length | ||||
PLC link | Communication patterns | Write, read, transfer | ||
Number of link settings | 512 settings max.*11 | |||
Link data size | 1440 words max. per setting (bit: 720 words, word: 720 words), 737280 words max. (total) (1440 words × 512 settings) | |||
Data unit | 1 word | |||
Number of connected models | 16 models max.*11 | |||
Number of connected units | 64 max.*11 | |||
Trigger types | Cyclic/event (64 settings max. for event*11) | |||
Update interval | 1 to 65535 ms | |||
*1 10 Mbps/100 Mbps/1000 Mbps MDI/MDI-X automatic switching function supported *2 STP = Shielded twisted pair cable; UTP = Unshielded twisted pair cable *3 The maximum cable length refers to the distance between the KV-XLE02 and the Ethernet switch. *4 The maximum number of connection is not limited when an Ethernet switch is used. *5 Modbus is a registered trademark or trademark of Schneider Electric. *6 SLMP is a registered trademark or trademark of Mitsubishi Electric Corporation. *7 EtherCAT® is fixed at 100 Mbps. It is not usable at different transmission rates. *8 CC-Link IE Field is fixed at 1000 Mbps. It is not usable at different transmission rates. *9 Industrial network trademarks • EtherNet/IP™ is a registered trademark or trademark of ODVA. • PROFINET is a registered trademark or trademark of PROFIBUS Nutzerorganisation e.V. • EtherCAT® is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany • CC-Link IE Field is a registered trademark or trademark of Mitsubishi Electric Corporation. *10 The max. is 160 when “Standard” is set for the number of communication commands in Unit Editor and 320 when “Extended” is set. *11 Total for one KV-XLE02 unit. |