Electrical data |
---|
Frequency AC [Hz] | 47…64 |
Operating voltage tolerance [%] | 15…20 |
Nominal voltage AC [V] | < 400 |
Input voltage range AC [V] | 380…480 |
Output voltage DC [V] | 24…28 |
Protection class | I; (IEC 61140) |
Overvoltage protection | yes; (< 32 DC) |
Output voltage [V] | adjustable; output voltage to SELV, PELV |
Max. output current at min. output voltage [A] | 40 |
Max. output current at max. output voltage [A] | 34.3 |
Max. output current peak at min. output voltage [A] | 60 |
Max. output current peak at max. output voltage [A] | 51.5 |
Output power (permanent) [W] | 960 |
Output power (peak) [W] | 1440 |
Note on output power (peak) | if consumption > 4 s the power is automatically reduced to the output power |
|
Power factor (nominal voltage 400 V AC / 50 Hz) | 0.88 |
Note on power factor (nominal voltage 400 V AC / 50 Hz) | with symmetrical phase voltage |
|
Power factor (nominal voltage 480 V AC / 50 Hz) | 0.9 |
Note on power factor (nominal voltage 480 V AC / 50 Hz) | with symmetrical phase voltage |
|
Power reserve [%] | 50 |
Number of output circuits | 1 |
Max. residual ripple [mV] | 100 |
Switch-on peak current (nominal voltage 400 V AC / 60 Hz) [A] | 4.5 |
Switch-on peak current (nominal voltage 480 V AC / 50 Hz) [A] | 4.5 |
Inrush current limitation | yes |
Efficiency (nominal voltage 400 V AC / 60 Hz) [%] | 95.3 |
Efficiency (nominal voltage 480 V AC / 50 Hz) [%] | 95.2 |
External input protection | ≥ B-6 A / ≥ C-6 A |
Derating [W/K] | 24 (60…70 °C) |
Mains buffering time (nominal voltage 400 V AC / 60 Hz) [ms] | 25 |
Mains buffering time (nominal voltage 480 V AC / 50 Hz) [ms] | 25 |
Input current (nominal voltage 400 V AC / 60 Hz) [A] | 1.65 |
Input current (nominal voltage 480 V AC / 50 Hz) [A] | 1.35 |
Power loss (nominal voltage 400 V AC / 60 Hz) [W] | 47.3 |
Power loss (nominal voltage 480 V AC / 50 Hz) [W] | 48.4 |
Back feeding protection [V] | 35 |
Outputs |
---|
Short-circuit proof | yes |
Overload protection | yes |
Overload performance | output current constant |
Type DC-OK signal | relay output |
Reliability of the DC OK signal | 60 V DC (0.3 A) / 30 V DC (1 A) / 30 V AC (0.5 A) |
Operating conditions |
---|
Ambient temperature [°C] | -25…70 |
Note on ambient temperature | observe the free space for convection (see operating instructions) |
|
Storage temperature [°C] | -40…85 |
Max. relative air humidity [%] | 95; (IEC 60068-2-30) |
Protection | IP 20; (EN 60529) |
Degree of soiling | 2; (IEC 62103: conductive soiling not permitted) |
Mechanical data |
---|
Weight [g] | 1754.5 |
Type of mounting | rail; (TH35 (EN 60715)) |
Dimensions [mm] | 124 x 110 x 130.7 |
Materials | steel sheet |
Displays / operating elements |
---|
Display | DC ok | 1 x LED | overload | 1 x LED |
|
Remarks |
---|
Remarks | Series connection of outputs only applies to identical units up to max. 150 V DC overall voltage |
|
Pack quantity | 1 pcs. |
Electrical connection |
---|
Connection | screw terminals: |