| Product characteristics | 
|---|
| Output signal | switching signal; IO-Link; (configurable) | 
| Measuring range | | 0…2.5 bar | 0…2500 mbar | 0…36.3 psi | 0…250 kPa | 
 | 
| Process connection | threaded connection G 1/4 internal thread | 
| Application | 
|---|
| Special feature | Gold-plated contacts | 
| Application | for industrial applications | 
| Media | liquids and gases | 
| Cannot be used for | oils | 
| Medium temperature [°C] | -25…80 | 
| Min. bursting pressure |  | 
| Pressure rating |  | 
| Type of pressure | relative pressure | 
| Electrical data | 
|---|
| Operating voltage [V] | 18…36 DC; (according to EN 50178 SELV/PELV) | 
| Current consumption [mA] | < 50 | 
| Min. insulation resistance [MΩ] | 100; (500 V DC) | 
| Protection class | III | 
| Reverse polarity protection | yes | 
| Overvoltage protection | yes; (< 40 V) | 
| Power-on delay time [s] | 0.3 | 
| Integrated watchdog | yes | 
| Inputs / outputs | 
|---|
| Number of inputs and outputs | Number of digital outputs: 2 | 
| Outputs | 
|---|
| Total number of outputs | 2 | 
| Output signal | switching signal; IO-Link; (configurable) | 
| Electrical design | PNP/NPN | 
| Number of digital outputs | 2 | 
| Output function | normally open / normally closed; (parameterisable) | 
| Max. voltage drop switching output DC [V] | 2 | 
| Permanent current rating of switching output DC [mA] | 250 | 
| Switching frequency DC [Hz] | < 170 | 
| Short-circuit protection | yes | 
| Type of short-circuit protection | pulsed | 
| Measuring/setting range | 
|---|
| Measuring range | | 0…2.5 bar | 0…2500 mbar | 0…36.3 psi | 0…250 kPa | 
 | 
| Set point SP | | 0.02…2.5 bar | 0.4…36.2 psi | 2…250 kPa | 
 | 
| Reset point rP | | 0.01…2.49 bar | 0.2…36 psi | 1…249 kPa | 
 | 
| In steps of |  | 
| Factory setting | |  | SP1 = 0.63 bar | rP1 = 0.58 bar |  |  | SP2 = 1.88 bar | rP2 = 1.83 bar | 
 | 
| Accuracy / deviations | 
|---|
| Switch point accuracy [% of the span] | < ± 0,5 | 
| Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) | 
| Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) | 
| Hysteresis deviation [% of the span] | < ± 0,25 | 
| Long-term stability [% of the span] | < ± 0,05; (per 6 months) | 
| Temperature coefficient zero point [% of the span / 10 K] | 0,2; (-20…80 °C) | 
| Temperature coefficient span [% of the span / 10 K] | 0,2; (-20…80 °C) | 
| Response times | 
|---|
| Delay time programmable dS, dr [s] | 0; 0,2…50 | 
| Software / programming | 
|---|
| Parameter setting options | hysteresis / window; normally open / normally closed; diagnostic function; switching logic; switch-on/switch-off delay; Damping; Display unit | 
| Interfaces | 
|---|
| Communication interface | IO-Link | 
| Transmission type | COM2 (38,4 kBaud) | 
| IO-Link revision | 1.1 | 
| Profiles | no profile | 
| SIO mode | yes | 
| Required master port type | A | 
| Process data analogue | 1 | 
| Process data binary | 2 | 
| Min. process cycle time [ms] | 2.3 | 
| Supported DeviceIDs | | Type of operation | DeviceID |  | Default | 312 | 
 | 
| Operating conditions | 
|---|
| Ambient temperature [°C] | -20…80 | 
| Storage temperature [°C] | -40…100 | 
| Protection | IP 67 | 
| Mechanical data | 
|---|
| Weight [g] | 261.5 | 
| Materials | stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); PC; PBT; PEI; FKM; EPDM/X; PTFE | 
| Materials (wetted parts) | stainless steel (1.4404 / 316L); ceramics (99.9 % Al2O3); sealing of the measuring cell: EPDM | 
| Min. pressure cycles | 100 million | 
| Process connection | threaded connection G 1/4 internal thread | 
| Displays / operating elements | 
|---|
| Display | | Display unit | 3 x LED, green |  | switching status | 2 x LED, yellow |  | function display | alphanumeric display, 4-digit |  | measured values | alphanumeric display, 4-digit | 
 | 
| Remarks | 
|---|
| Notes | discontinued article | 
| Pack quantity | 1 pcs. | 
| Electrical connection | 
|---|
|  | Connector: 1 x M12; Contacts: gold-plated |