| Product characteristics | 
|---|
| Output signal | switching signal | 
| Measuring range | | 0…400 bar | 0…5800 psi | 0…40 MPa | 
 | 
| Process connection | threaded connection 1/4″ NPT internal thread | 
| Application | 
|---|
| Application | for industrial applications | 
| Media | liquids and gases | 
| Conditionally suitable for | use in gases at pressures > 25 bar only on request | 
| Medium temperature [°C] | -25…80 | 
| Min. bursting pressure | | 1000 bar | 14500 psi | 100 MPa | 
 | 
| Pressure rating |  | 
| Type of pressure | relative pressure | 
| Electrical data | 
|---|
| Operating voltage tolerance [%] | 5…10 | 
| Operating voltage [V] | 85…265 AC | 
| Nominal voltage AC [V] | < 250 | 
| Current consumption [mA] | < 10 | 
| Min. insulation resistance [MΩ] | 100; (500 V DC) | 
| Protection class | II | 
| Reverse polarity protection | no | 
| Power-on delay time [s] | 0.2 | 
| Integrated watchdog | yes | 
| Inputs / outputs | 
|---|
| Number of inputs and outputs | Number of digital outputs: 1 | 
| Outputs | 
|---|
| Total number of outputs | 1 | 
| Output signal | switching signal | 
| Electrical design | Triac | 
| Number of digital outputs | 1 | 
| Output function | normally open / normally closed; (parameterisable) | 
| Max. voltage drop switching output AC [V] | 2 | 
| Permanent current rating of switching output AC [mA] | 250; ((…70 °C) 1000 (…60 °C) 1500 (…45 °C) 2500 (…20 °C)) | 
| Switching frequency AC [Hz] | < 160 | 
| Short-circuit proof | no | 
| Overload protection | no | 
| Measuring/setting range | 
|---|
| Measuring range | | 0…400 bar | 0…5800 psi | 0…40 MPa | 
 | 
| Set point SP | | 4…400 bar | 60…5800 psi | 0.4…40 MPa | 
 | 
| Reset point rP | | 2…398 bar | 30…5770 psi | 0.2…39.8 MPa | 
 | 
| In steps of |  | 
| Accuracy / deviations | 
|---|
| Switch point accuracy [% of the span] | < ± 1,0 | 
| Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) | 
| Linearity deviation [% of the span] | < ± 0,5 | 
| Hysteresis deviation [% of the span] | < ± 0,1 | 
| Long-term stability [% of the span] | < ± 0,1; (per year) | 
| Temperature coefficient zero point [% of the span / 10 K] | < ± 0,2; (-25…80 °C) | 
| Temperature coefficient span [% of the span / 10 K] | < ± 0,3; (-25…80 °C) | 
| Response times | 
|---|
| Delay time programmable dS, dr [s] | 0, 0,2,…10, 11,…50 | 
| Damping for the switching output dAP [s] | 0…4 | 
| Software / programming | 
|---|
| Adjustment of the switch point | programming button | 
| Parameter setting options | hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit | 
| Operating conditions | 
|---|
| Ambient temperature [°C] | -25…80 | 
| Storage temperature [°C] | -40…100 | 
| Protection | IP 67 | 
| Mechanical data | 
|---|
| Weight [g] | 399 | 
| Materials | stainless steel (1.4301 / 304); PC; PBT; PA; FKM | 
| Materials (wetted parts) | stainless steel (1.4305 / 303); ceramics; FKM | 
| Min. pressure cycles | 100 million | 
| Process connection | threaded connection 1/4″ NPT internal thread | 
| Restrictor element integrated | yes | 
| Displays / operating elements | 
|---|
| Display | | switching status | LED, red |  | function display | 7-segment LED display |  | measured values | 7-segment LED display | 
 | 
| Electrical connection | 
|---|
| Required protection | miniature fuse to IEC60127-2 sheet 1; ≤ 5 A; fast acting | 
| Remarks | 
|---|
| Remarks |  | 
| Pack quantity | 1 pcs. | 
| Electrical connection | 
|---|
| Connection | Connector: 1 x 1/2″ |