Product characteristics |
---|
Output signal | switching signal |
Measuring range | -1…1 bar | -1000…1000 mbar | -14.5…14.5 psi | -100…100 kPa |
|
Process connection | threaded connection G 1/8 internal thread |
Application |
---|
Special feature | Gold-plated contacts |
Application | for industrial applications |
Media | compressed air |
Conditionally suitable for | other media on request |
Medium temperature [°C] | 0…60 |
Min. bursting pressure | 30000 mbar | 435 psi | 3000 kPa |
|
Pressure rating | 20000 mbar | 290 psi | 2000 kPa |
|
Type of pressure | relative pressure; vacuum |
Electrical data |
---|
Operating voltage [V] | 18…36 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA] | < 50 |
Min. insulation resistance [MΩ] | 100; (500 V DC) |
Protection class | III |
Reverse polarity protection | yes |
Overvoltage protection | yes; (< 40 V) |
Power-on delay time [s] | 0.3 |
Integrated watchdog | yes |
Inputs / outputs |
---|
Number of inputs and outputs | Number of digital outputs: 2 |
Outputs |
---|
Total number of outputs | 2 |
Output signal | switching signal |
Electrical design | PNP/NPN |
Number of digital outputs | 2 |
Output function | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 250 |
Switching frequency DC [Hz] | < 170 |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Measuring/setting range |
---|
Measuring range | -1…1 bar | -1000…1000 mbar | -14.5…14.5 psi | -100…100 kPa |
|
Set point SP | -975…1000 mbar | -14.1…14.5 psi | -97.5…100 kPa |
|
Reset point rP | -980…995 mbar | 14.2…14.4 psi | -98…99.5 kPa |
|
In steps of | |
Factory setting | | SP1 = -500 mbar | rP1 = -540 mbar | | SP2 = 500 mbar | rP2 = 460 mbar |
|
Accuracy / deviations |
---|
Switch point accuracy [% of the span] | < ± 0,5 |
Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) |
Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
Hysteresis deviation [% of the span] | < ± 0,25 |
Long-term stability [% of the span] | < ± 0,05; (per 6 months) |
Temperature coefficient zero point [% of the span / 10 K] | 0,2; (0…60 °C) |
Temperature coefficient span [% of the span / 10 K] | 0,2; (0…60 °C) |
Response times |
---|
Delay time programmable dS, dr [s] | 0; 0,2…50 |
Software / programming |
---|
Parameter setting options | hysteresis / window; normally open / normally closed; diagnostic function; switching logic; switch-on/switch-off delay; Damping; Display unit |
Operating conditions |
---|
Ambient temperature [°C] | -25…85 |
Storage temperature [°C] | -25…85 |
Protection | IP 67 |
Mechanical data |
---|
Weight [g] | 173 |
Materials | stainless steel (1.4301 / 304); PPS; PC; PBT; PEI; FKM |
Materials (wetted parts) | stainless steel (1.4567 / 304Cu); brass; FKM; PPS; silicon (coated) |
Min. pressure cycles | 50 million |
Process connection | threaded connection G 1/8 internal thread |
Displays / operating elements |
---|
Display | Display unit | 3 x LED, green | switching status | 2 x LED, yellow | function display | alphanumeric display, 4-digit | measured values | alphanumeric display, 4-digit |
|
Accessories |
---|
Accessories (optional) | mounting set for DIN rail: TH 35-7,5 / EN60715, E37340 | Adapter: R1/8 – R1/8, E37350 | Thread extension: 1/8″, E30075 | push-in air fitting for tube: Ø 6 mm, E30076 | push-in air fitting for tube: Ø 8 mm, E30077 |
|
Remarks |
---|
Pack quantity | 1 pcs. |
Electrical connection |
---|
| Connector: 1 x M12; Contacts: gold-plated |