| Product characteristics | 
|---|
| Electrical design | PNP/NPN; (parameterisable) | 
| Output function | normally open / normally closed; (parameterisable) | 
| Communication interface | IO-Link | 
| Housing | threaded type | 
| Dimensions [mm] | M18 x 1 / L = 60 | 
| Electrical data | 
|---|
| Operating voltage [V] | 15…30 DC | 
| Current consumption [mA] | < 30 | 
| Protection class | II | 
| Reverse polarity protection | yes | 
| Outputs | 
|---|
| Electrical design | PNP/NPN; (parameterisable) | 
| Output function | normally open / normally closed; (parameterisable) | 
| Max. voltage drop switching output DC [V] | 2.5 | 
| Permanent current rating of switching output DC [mA] | 100 | 
| Switching frequency DC [Hz] | 300 | 
| Analogue current output [mA] | 4…20; (linear; gradient: 2,222 mA/mm; for frontal approach and for target made of mild steel: 24 x 24 x 1 mm) | 
| Max. load [Ω] | 500; (Ub <=18 V; ; Max. load <=400 Ω) | 
| Short-circuit protection | yes | 
| Overload protection | yes | 
| Detection zone | 
|---|
| Measuring range [mm] | 0.8…8 | 
| Switch point IO-Link [mm] | 1.5…7.48 | 
| Accuracy / deviations | 
|---|
| Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.5 / copper: 0.4 | 
| Hysteresis [% of Sr] | 3…15 | 
| Note on hysteresis |  | 
| Linearity error of analogue output [%] | ± 1; (of the final value of the measuring range) | 
| Repeatability analogue output [%] | ± 1; (of the final value of the measuring range) | 
| Temperature coefficient [%/K vom MEW] | ±0,15 | 
| Temperature drift [% vom MEW] | ±5 | 
| Response times | 
|---|
| Response time [ms] | < 10 | 
| Interfaces | 
|---|
| Communication interface | IO-Link | 
| Transmission type | COM2 (38,4 kBaud) | 
| IO-Link revision | 1.1 | 
| SDCI standard | IEC 61131-9 | 
| Profiles | Smart Sensor: Identification and diagnosis; Multi-channel, two setpoint switching sensor, type 0 Generic Profiled Sensor; Teach Channel | 
| SIO mode | yes | 
| Required master port type | A | 
| Min. process cycle time [ms] | 3.2 | 
| IO-Link process data (cyclical) | | function | bit length |  | process value | 16 |  | device status | 4 |  | binary switching information | 2 | 
 | 
| IO-Link functions (acyclical) | switching cycles counter; switch-on cycle counter; operating hours counter; internal temperature; application specific tag | 
| Supported DeviceIDs | | Type of operation | DeviceID |  | Default | 1205 | 
 | 
| Note | | For further information please see the IODD PDF file under “Downloads” | 
 | 
| Operating conditions | 
|---|
| Ambient temperature [°C] | -25…80 | 
| Protection | IP 65; IP 66; IP 67; IP 68; IP 69K | 
| Mechanical data | 
|---|
| Weight [g] | 47.38 | 
| Housing | threaded type | 
| Mounting | non-flush mountable | 
| Dimensions [mm] | M18 x 1 / L = 60 | 
| Thread designation | M18 x 1 | 
| Materials | Housing: brass white bronze coated; sensing face: PBT orange; LED-Fenster: PEI; lock nuts: brass white bronze coated | 
| Tightening torque [Nm] | 25 | 
| Displays / operating elements | 
|---|
| Display | | target in measuring range | 4 x LED, yellow lights |  | target outside measuring range | 4 x LED, yellow flashing | 
 | 
| Accessories | 
|---|
| Accessories (supplied) |  | 
| Remarks | 
|---|
| Pack quantity | 1 pcs. | 
| Electrical connection – plug | 
|---|
| Connection | Connector: 1 x M12 |