|  Product characteristics | 
|---|
|  Type of light |  red light | 
|  Communication interface |  IO-Link | 
|  Housing |  rectangular | 
|  Dimensions [mm] |  M18 x 1 | 
|  Application | 
|---|
|  Special feature |  Background suppression | 
|  Function principle |  Diffuse reflection sensor | 
|  Electrical data | 
|---|
|  Operating voltage [V] |  10…30 DC | 
|  Current consumption [mA] |  25 | 
|  Protection class |  III | 
|  Reverse polarity protection |  yes | 
|  Type of light |  red light | 
|  Wave length [nm] |  645 | 
|  Outputs | 
|---|
|  Electrical design |  NPN | 
|  Output function |  light-on mode | 
|  Max. voltage drop switching output DC [V] |  2.5 | 
|  Permanent current rating of switching output DC [mA] |  200 | 
|  Switching frequency DC [Hz] |  1000 | 
|  Short-circuit protection |  yes | 
|  Type of short-circuit protection |  pulsed | 
|  Overload protection |  yes | 
|  Detection zone | 
|---|
|  Range [mm] |  < 200; (white paper 200 x 200 mm 90% remission) | 
|  Range on white object (90 % remission) [mm] |  < 200 | 
|  Range on grey object (18 % remission) [mm] |  < 200 | 
|  Range on black object (6 % remission) [mm] |  < 190 | 
|  Range adjustable |  no | 
|  Max. light spot diameter [mm] |  13 | 
|  Light spot dimensions refer to |  at maximum range | 
|  Background suppression available |  yes | 
|  Interfaces | 
|---|
|  Communication interface |  IO-Link | 
|  Transmission type |  COM2 (38,4 kBaud) | 
|  IO-Link revision |  1.1 | 
|  SDCI standard |  IEC 61131-9 | 
|  Profiles |  Measuring Sensor, Identification and Diagnosis, Switching Signal Channel, Teach Channel | 
|  SIO mode |  yes | 
|  Required master port type |  A | 
|  Min. process cycle time [ms] |  10 | 
|  IO-Link process data (cyclical) | |  function |  bit length |  |  process value |  16 |  |  device status |  4 |  |  binary switching information |  1 |  
  | 
|  IO-Link functions (acyclical) |  application specific tag; operating hours counter; switching cycles counter | 
|  Supported DeviceIDs | |  Type of operation |  DeviceID |  |  Default |  1139 |  
  | 
|  Note | |  For further information please see the IODD PDF file under “Downloads” |  
  | 
|  Operating conditions | 
|---|
|  Ambient temperature [°C] |  -25…80 | 
|  Storage temperature [°C] |  -40…80 | 
|  Protection |  IP 65; IP 67; IP 68; IP 69K | 
|  Mechanical data | 
|---|
|  Weight [g] |  120.5 | 
|  Housing |  rectangular | 
|  Dimensions [mm] |  M18 x 1 | 
|  Thread designation |  M18 x 1 | 
|  Materials |  1.4542 (17-4 PH / 630); PEI | 
|  Lens material |  | 
|  Lens alignment |  side lens | 
|  Displays / operating elements | 
|---|
|  Display | |  switching status |  1 x LED, yellow |  |  operation |  1 x LED, green |  
  | 
|  Accessories | 
|---|
|  Accessories (supplied) | |  lock nut: 1, stainless steel |  
  | 
|  Remarks | 
|---|
|  Pack quantity |  1 pcs. | 
|  Electrical connection | 
|---|
|  Connection |  Connector: 1 x M12 | 
|  Other data | 
|---|
|  Repeatability / precision: 6 σ | 
|---|
 |  repeatability of the measured values |  |  |  Abstand |  white (90 % remission) |  black (6 %…90 % remission) |  |  20 mm |  0.5 mm |  1.0 mm |  |  50 mm |  0.8 mm |  2.0 mm |  |  100 mm |  1.5 mm |  4.5 mm |  |  150 mm |  3.0 mm |  9.0 mm |  |  200 mm |  6.0 mm |  20.0 mm |   |  |  |   |  Accuracy |  |  |  Abstand |  white (90 % remission) |  black (6 %…90 % remission) |  |  20 mm |  ± 2.0 mm |  ± 2.5 mm |  |  50 mm |  ± 3.5 mm |  ± 4.5 mm |  |  100 mm |  ± 6.0 mm |  ± 7.5 mm |  |  150 mm |  ± 7.5 mm |  ± 11.0 mm |  |  200 mm |  ± 10.0 mm |  ± 17.0 mm |  
  | 
|  The values apply at |  |  |  Extraneous light on the object |  < 10 klx |  |  constant ambient conditions |  23 °C / 960 hPa |  |  minimum power-on time in minutes |  10 |  
  |