|  Product characteristics | 
|---|
|  Number of inputs and outputs |  Number of digital outputs: 2; Number of analogue outputs: 1 | 
|  Measuring range | |  25…7945 scfh |  0.4…132.4 scfm |  1.2…340.2 ft/s |  
  | 
|  Process connection |  threaded connection 1″ NPT DN25 | 
|  Application | 
|---|
|  Application |  for industrial applications | 
|  Media |  Argon (Ar); carbon dioxide (CO2); nitrogen (N2); compressed air | 
|  Medium temperature [°F] |  14…140 | 
|  Min. bursting pressure [psi] |  928 | 
|  Pressure rating [psi] |  232 | 
|  Electrical data | 
|---|
|  Operating voltage [V] |  18…30 DC; (according to EN 50178 SELV/PELV) | 
|  Current consumption [mA] |  < 80 | 
|  Protection class |  III | 
|  Reverse polarity protection |  yes | 
|  Power-on delay time [s] |  1 | 
|  Inputs / outputs | 
|---|
|  Number of inputs and outputs |  Number of digital outputs: 2; Number of analogue outputs: 1 | 
|  Inputs | 
|---|
|  Inputs |  counter reset | 
|  Outputs | 
|---|
|  Output signal |  switching signal; analogue signal; pulse signal; IO-Link; (configurable) | 
|  Electrical design |  PNP/NPN | 
|  Number of digital outputs |  2 | 
|  Output function |  normally open / normally closed; (parameterisable) | 
|  Max. voltage drop switching output DC [V] |  2.5 | 
|  Permanent current rating of switching output DC [mA] |  150; (per output) | 
|  Number of analogue outputs |  1 | 
|  Analogue current output [mA] |  4…20; (scalable) | 
|  Max. load [Ω] |  500 | 
|  Pulse output |  consumed quantity meter | 
|  Short-circuit protection |  yes | 
|  Type of short-circuit protection |  pulsed | 
|  Overload protection |  yes | 
|  Measuring/setting range | 
|---|
|  Measuring range | |  25…7945 scfh |  0.4…132.4 scfm |  1.2…340.2 ft/s |  
  | 
|  Display range | |  0…9535 scfh |  0…158.9 scfm |  0…408.2 ft/s |  
  | 
|  Resolution |  | 
|  Set point SP | |  69…7943 scfh |  1.1…132.4 scfm |  3…340.1 ft/s |  
  | 
|  Reset point rP | |  30…7904 scfh |  0.5…131.7 scfm |  1.3…338.4 ft/s |  
  | 
|  Analogue start point ASP | |  0…6357 scfh |  0…105.9 scfm |  0…272.2 ft/s |  
  | 
|  Analogue end point AEP | |  1589…7946 scfh |  26.5…132.4 scfm |  68…340.2 ft/s |  
  | 
|  Low flow cut-off LFC | |  9…85 scfh |  0.2…1.4 scfm |  0.4…3.6 ft/s |  
  | 
|  In steps of |  | 
|  Pressure monitoring | 
|---|
|  Measuring range [psi] |  -15…232 | 
|  Display range [psi] |  -15…290 | 
|  Resolution [psi] |  1 | 
|  Set point SP [psi] |  -13…232 | 
|  Reset point rP [psi] |  -15…231 | 
|  Analogue start point [psi] |  -15…186 | 
|  Analogue end point [psi] |  32…232 | 
|  In steps of [psi] |  1 | 
|  Volumetric flow quantity monitoring | 
|---|
|  Measuring range | |  0…100000000 m³ |  0…353146667.2 scf |  
  | 
|  Display range | |  0…100000000 m³ |  0…353146667.2 scf |  
  | 
|  Set point SP | |  0.001…10000000 m³ |  0.05…353146667.2 scf |  
  | 
|  Pulse value | |  0.001…10000000 m³ |  0.05…353146667.2 scf |  
  | 
|  In steps of |  | 
|  Pulse length [s] |  0.007…2 | 
|  Temperature monitoring | 
|---|
|  Measuring range |  | 
|  Display range |  | 
|  Resolution |  | 
|  Set point SP |  | 
|  Reset point rP |  | 
|  Analogue start point |  | 
|  Analogue end point |  | 
|  In steps of |  | 
|  Accuracy / deviations | 
|---|
|  Temperature coefficient [1/K] |  ± 0,07 % MW | 
|  Accuracy (in the measuring range) |  ± (6 % MW + 0,6 % MEW); (at medium temperature 73 °F) | 
|  Repeatability |  ± (0,4 % MW + 0,1 % MEW) | 
|  Pressure monitoring | 
|---|
|  Repeatability [% of the final value] |  ± 0,2 | 
|  Characteristics deviation [% of the final value] |  < ± 0,5; (BFSL = Best Fit Straight Line) | 
|  Greatest TEMPCO of the span [% MEW / 10 K] |  ± 0,15 | 
|  Greatest TEMPCO of the zero point [% MEW / 10 K] |  ± 0,25 | 
|  Temperature monitoring | 
|---|
|  Accuracy [K] |  ± 0,5; (medium flow in the limit area of the flow measurement range) | 
|  Response times | 
|---|
|  Response time [s] |  0.1; (dAP = 0) | 
|  Damping for the switching output dAP [s] |  0…5 | 
|  Pressure monitoring | 
|---|
|  Response time [s] |  0.05 | 
|  Temperature monitoring | 
|---|
|  Dynamic response T05 / T09 [s] |  T09 = 0,5 | 
|  Software / programming | 
|---|
|  Parameter setting options |  hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser | 
|  Interfaces | 
|---|
|  Communication interface |  IO-Link | 
|  Transmission type |  COM2 (38,4 kBaud) | 
|  IO-Link revision |  1.1 | 
|  SDCI standard |  IEC 61131-9 CDV | 
|  Profiles |  Digital Measuring Sensor (0x800A), Identification and Diagnosis (0x4000) | 
|  SIO mode |  yes | 
|  Required master port type |  A | 
|  Process data analogue |  8 | 
|  Process data binary |  2 | 
|  Min. process cycle time [ms] |  7.2 | 
|  Supported DeviceIDs | |  Type of operation |  DeviceID |  |  Default |  1292 |  
  | 
|  Operating conditions | 
|---|
|  Ambient temperature [°F] |  32…140 | 
|  Storage temperature [°C] |  -4…185 | 
|  Max. relative air humidity [%] |  90 | 
|  Protection |  IP 65; IP 67 | 
|  Mechanical data | 
|---|
|  Weight [g] |  1608.8 | 
|  Materials |  PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); steel (1.5523) galvanised; 2.0401 (brass / CW614N); FKM | 
|  Materials (wetted parts) |  stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); FKM; ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate | 
|  Process connection |  threaded connection 1″ NPT DN25 | 
|  Displays / operating elements | 
|---|
|  Display |  |  colour display 1,44″, 128 x 128 pixels |   |  2 x LED, yellow |  
  | 
|  Remarks | 
|---|
|  Remarks | |  MW = measured value |  |  MEW = Final value of the measuring range |  |  Standard conditions: 1013.25 mbar / 15 °C / 0 % relative humidity |  |  For information about installation and operation please see the operating instructions. |  
  | 
|  Pack quantity |  1 pcs. | 
|  Electrical connection | 
|---|
|  Connection |  Connector: 1 x M12 |