| Product characteristics |
|---|
| Electrical design | PNP |
| Output function | normally open / normally closed; (parameterisable) |
| Sensing range [mm] | 200…2200; (Target: 200 x 200 mm) |
| Communication interface | IO-Link |
| Housing | threaded type |
| Dimensions [mm] | M18 x 1 / L = 97.5 |
| Electrical data |
|---|
| Operating voltage [V] | 10…30 DC; (“supply class 2” to cULus) |
| Current consumption [mA] | 55 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | < 0.3 |
| Converter frequency [kHz] | 200 |
| Inputs / outputs |
|---|
| Number of inputs and outputs | Number of digital outputs: 2 |
| Outputs |
|---|
| Total number of outputs | 2 |
| Electrical design | PNP |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] | 2.2 |
| Permanent current rating of switching output DC [mA] | 100 |
| Switching frequency DC [Hz] | 2 |
| Short-circuit protection | yes |
| Overload protection | yes |
| Detection zone |
|---|
| Sensing range [mm] | 200…2200; (Target: 200 x 200 mm) |
| Blind zone [mm] | 200 |
| Angle of aperture cylindrical [°] | 14; (±2) |
| Max. deviation from the 90° angle sensor/object [°] | ± 4 |
| Accuracy / deviations |
|---|
| Temperature compensation | yes |
| Hysteresis [%] | < 2 |
| Switch point drift [%] | -2…2 |
| Notes on the accuracy / deviation | The indicated values are reached after a warm-up time of min. 20 minutes |
| Repeatability | 1 % |
| Resolution [mm] | 1 |
| Software / programming |
|---|
| Parameter setting options | hysteresis / window; second switch point; Switch-on and switch-off delay; switch-on operations; Teach function; light-on/dark-on mode |
| Interfaces |
|---|
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor: Device Identification; Multi-channel, two setpoint switching sensor, type 0 Generic Profiled Sensor; Process Data Variable; Device Diagnosis; Teach Channel |
| SIO mode | yes |
| Required master port type | A |
| Min. process cycle time [ms] | 3.2 |
| IO-Link process data (cyclical) | | function | bit length | | process value | 16 | | device status | 4 | | binary switching information | 2 |
|
| IO-Link functions (acyclical) | application specific tag; operating hours counter |
| Supported DeviceIDs | | Type of operation | DeviceID | | Default | 701 |
|
| Note | | For further information please see the IODD PDF file under “Downloads” |
|
| Operating conditions |
|---|
| Ambient temperature [°C] | -20…70 |
| Storage temperature [°C] | -30…80 |
| Protection | IP 67 |
| Mechanical data |
|---|
| Weight [g] | 102 |
| Housing | threaded type |
| Dimensions [mm] | M18 x 1 / L = 97.5 |
| Thread designation | M18 x 1 |
| Materials | stainless steel (1.4404 / 316L); PA; epoxy glass ceramics |
| Tightening torque [Nm] | 50 |
| Displays / operating elements |
|---|
| Display | | switching status | 2 x LED, yellow | | echo | 1 x LED, green |
|
| Teach function | yes |
| Accessories |
|---|
| Accessories (supplied) | | lock nuts: 2, stainless steel |
|
| Remarks |
|---|
| Remarks | | operating voltage “supply class 2” according to cULus |
|
| Pack quantity | 1 pcs. |
| Electrical connection |
|---|
| Connection | Connector: 1 x M12 |