|  Product characteristics | 
|---|
|  Electrical design |  PNP | 
|  Output function |  normally open / normally closed; (parameterisable) | 
|  Sensing range [mm] |  350…6000; (Target: 400 x 400 mm) | 
|  Communication interface |  IO-Link | 
|  Housing |  threaded type | 
|  Dimensions [mm] |  M30 x 1.5 / L = 103.8 | 
|  Electrical data | 
|---|
|  Operating voltage [V] |  10…30 DC | 
|  Current consumption [mA] |  < 30 | 
|  Protection class |  III | 
|  Reverse polarity protection |  yes | 
|  Power-on delay time [s] |  < 0.3 | 
|  Converter frequency [kHz] |  75 | 
|  Inputs / outputs | 
|---|
|  Number of inputs and outputs |  Number of digital outputs: 2 | 
|  Outputs | 
|---|
|  Total number of outputs |  2 | 
|  Electrical design |  PNP | 
|  Number of digital outputs |  2 | 
|  Output function |  normally open / normally closed; (parameterisable) | 
|  Max. voltage drop switching output DC [V] |  2.2 | 
|  Permanent current rating of switching output DC [mA] |  100 | 
|  Switching frequency DC [Hz] |  1 | 
|  Short-circuit protection |  yes | 
|  Overload protection |  yes | 
|  Detection zone | 
|---|
|  Sensing range [mm] |  350…6000; (Target: 400 x 400 mm) | 
|  Blind zone [mm] |  350 | 
|  Angle of aperture cylindrical [°] |  15; (±2) | 
|  Max. deviation from the 90° angle sensor/object [°] |  ± 4 | 
|  Accuracy / deviations | 
|---|
|  Temperature compensation |  yes | 
|  Hysteresis [%] |  < 3 | 
|  Switch point drift [%] |  -5…5 | 
|  Notes on the accuracy / deviation |  The indicated values are reached after a warm-up time of min. 20 minutes | 
|  Repeatability |  1 % | 
|  Resolution [mm] |  3 | 
|  Software / programming | 
|---|
|  Parameter setting options |  hysteresis / window; second switch point; Switch-on and switch-off delay; switch-on operations; Teach function; light-on/dark-on mode | 
|  Interfaces | 
|---|
|  Communication interface |  IO-Link | 
|  Transmission type |  COM2 (38,4 kBaud) | 
|  IO-Link revision |  1.1 | 
|  SDCI standard |  IEC 61131-9 | 
|  Profiles |  Smart Sensor: Device Identification; Multi-channel, two setpoint switching sensor, type 0 Generic Profiled Sensor; Process Data Variable; Device Diagnosis; Teach Channel | 
|  SIO mode |  yes | 
|  Required master port type |  A | 
|  Min. process cycle time [ms] |  3.2 | 
|  IO-Link process data (cyclical) | |  function |  bit length |  |  process value |  16 |  |  device status |  4 |  |  binary switching information |  2 |  
  | 
|  IO-Link functions (acyclical) |  application specific tag; operating hours counter | 
|  Supported DeviceIDs | |  Type of operation |  DeviceID |  |  Default |  1096 |  
  | 
|  Note | |  For further information please see the IODD PDF file under “Downloads” |  
  | 
|  Operating conditions | 
|---|
|  Ambient temperature [°C] |  -20…70 | 
|  Storage temperature [°C] |  -30…80 | 
|  Protection |  IP 67 | 
|  Mechanical data | 
|---|
|  Weight [g] |  254.8 | 
|  Housing |  threaded type | 
|  Dimensions [mm] |  M30 x 1.5 / L = 103.8 | 
|  Thread designation |  M30 x 1.5 | 
|  Materials |  stainless steel (1.4404 / 316L); PA; epoxy glass ceramics | 
|  Tightening torque [Nm] |  100 | 
|  Displays / operating elements | 
|---|
|  Display | |  switching status |  2 x LED, yellow |  |  echo |  1 x LED, green |  
  | 
|  Teach function |  yes | 
|  Accessories | 
|---|
|  Accessories (supplied) | |  lock nuts: 2, stainless steel |  
  | 
|  Remarks | 
|---|
|  Remarks | |  operating voltage “supply class 2” according to cULus |  
  | 
|  Pack quantity |  1 pcs. | 
|  Electrical connection | 
|---|
|  Connection |  Connector: 1 x M12 |