| Electrical data |
|---|
| Frequency AC [Hz] | 47…64 |
| Operating voltage tolerance [%] | 10 |
| Operating voltage [V] | automatic range selection |
| Nominal voltage AC [V] | 110 / 230 |
| Input voltage range AC [V] | 100…120 / 200…240 |
| Protection class | I |
| Overvoltage protection | yes; (< 36 V) |
| Max. power-on delay time [ms] | 800 |
| Output voltage AS-i [V] | 30.5 |
| Output power (permanent) [W] | 244 |
| Output power (peak) [W] | 256 |
| Note on output power (peak) | | briefly to load bus capacities after power on |
|
| Power factor (nominal voltage 120 V AC / 60 Hz) | 0.59 |
| Power factor (nominal voltage 230 V AC / 50 Hz) | 0.51 |
| Power reserve [%] | 5 |
| Number of output circuits | 1 |
| Output current AS-i [A] | 8 |
| Max. residual ripple [mV] | 100 |
| Switch-on peak current (nominal voltage 120 V AC / 60 Hz) [A] | 3 |
| Switch-on peak current (nominal voltage 230 V AC / 50 Hz) [A] | 3 |
| Inrush current limitation | yes |
| Efficiency (nominal voltage 120 V AC / 60 Hz) [%] | 89.4 |
| Efficiency (nominal voltage 230 V AC / 50 Hz) [%] | 90.9 |
| External input protection | ≤ B-10 A / ≤ C-6 A |
| Derating [W/K] | 6 (60…70 °C) |
| Mains buffering time (nominal voltage 120 V AC / 60 Hz) [ms] | 44 |
| Mains buffering time (nominal voltage 230 V AC / 50 Hz) [ms] | 42 |
| Input current (nominal voltage 120 V AC / 60 Hz) [A] | 3.73 |
| Input current (nominal voltage 230 V AC / 50 Hz) [A] | 2.23 |
| Power loss (nominal voltage 120 V AC / 60 Hz) [W] | 28.9 |
| Power loss (nominal voltage 230 V AC / 50 Hz) [W] | 24.4 |
| Integrated data decoupling | yes |
| Back feeding protection [V] | 35 |
| Outputs |
|---|
| Short-circuit proof | yes |
| Overload protection | yes |
| Overload performance | output current constant |
| Parallel connection of outputs possible | no |
| Series connection of outputs possible | no |
| Operating conditions |
|---|
| Ambient temperature [°C] | -25…70 |
| Note on ambient temperature | | observe the free space for convection (see operating instructions) |
|
| Storage temperature [°C] | -40…85 |
| Max. relative air humidity [%] | 95; (IEC 60068-2-30) |
| Protection | IP 20 |
| Degree of soiling | 2; (IEC 62103: conductive soiling not permitted) |
| AS-i classification |
|---|
| AS-i certificate | 98501 |
| Mechanical data |
|---|
| Weight [g] | 898.5 |
| Type of mounting | rail; (TH35 (EN 60715)) |
| Dimensions [mm] | 124 x 62 x 120 |
| Materials | steel sheet |
| Displays / operating elements |
|---|
| Display | |
| Remarks |
|---|
| Pack quantity | 1 pcs. |
| Electrical connection |
|---|
| Connection | screw terminals: |