| Electrical data |
|---|
| Operating voltage [V] | 26.5…31.6 DC; (“supply class 2” to cULus) |
| Max. current consumption from AS-i [mA] | 250 |
| Max. current load total [A] | 4 |
| Additional voltage supply [V] | 10…30 DC; (AUX) |
| Integrated watchdog | yes |
| Inputs / outputs |
|---|
| Number of inputs and outputs | Number of digital inputs: 4; Number of digital outputs: 4 |
| Inputs |
|---|
| Number of digital inputs | 4 |
| Input circuit of digital inputs | PNP |
| Sensor supply of the inputs | AS-i |
| Voltage supply [V] | 20…30 |
| Max. total current rating of inputs [mA] | 200 |
| Input current limitation [mA] | 15 |
| Input current High [mA] | 6…10 |
| Input current Low [mA] | 0…2 |
| Min. switching level high signal [V] | 11 |
| Digital inputs protected against short circuits | yes |
| Outputs |
|---|
| Number of digital outputs | 4 |
| Circuit | PNP |
| Voltage range DC [V] | 10…30; (to PELV) |
| Max. current load per output [mA] | 2000; (utilisation category DC-13 (control of electromagnets): 20 W (IEC 60947-5-1)) |
| Short-circuit proof | yes |
| Electrically separated | yes |
| Operating conditions |
|---|
| Ambient temperature [°C] | -25…80 |
| Protection | IP 67; (when flat cables are used E7400x / E7401x) |
| AS-i classification |
|---|
| AS-i version | 3.0 |
| Extended addressing mode possible | yes |
| AS-i profile | S-7.A.7 |
| AS-i I/O configuration [hex] | 7 |
| AS-i ID code [hex] | A.7 |
| AS-i certificate | 126101 |
| Assignment of the data bits | | data bit | D0 | D1 | D2 | D3 | | input | 1 | 2 | 3 | 4 | | socket | I-1/2 | I-1/2 / I-2 | I-3/4 | I-3/4 / I-4 | | pin | 4 | 2 4 | 4 | 2 4 | | Output | 1 | 2 | 3 | 4 | | socket | O-1 | O-2 | O-3 | O-4 | | pin | 4 | 4 | 4 | 4 |
|
| Mechanical data |
|---|
| Weight [g] | 388.5 |
| Materials | PA; socket: brass nickel-plated; O-ring: FKM |
| Displays / operating elements |
|---|
| Display | | operation | LED, green | | errors | LED, red | | function | LED, yellow |
|
| Accessories |
|---|
| Accessories (optional) | | Stainless steel sleeve, for installation in case of high mechanical stress , E70402 |
|
| Remarks |
|---|
| Remarks | | Inputs and outputs must be electrically isolated. |
|
| Pack quantity | 1 pcs. |
| Electrical connection – Inputs |
|---|
| Connection | Connector: M12 |
| Electrical connection – Outputs |
|---|
| Connector: M12 |