Electrical data |
---|
Operating voltage [V] | 26.5…31.6 DC |
Max. current consumption from AS-i [mA] | 280 |
Integrated watchdog | yes |
Inputs / outputs |
---|
Number of inputs and outputs | Number of digital inputs: 4; Number of pneumatic outputs: 2 |
Inputs |
---|
Number of digital inputs | 4 |
Input circuit of digital inputs | PNP |
Sensor supply of the inputs | AS-i |
Voltage supply [V] | 20…30; (via flat cable) |
Max. total current rating of inputs [mA] | 200 |
Input current High [mA] | 6…10 |
Input current Low [mA] | 0…2 |
Min. switching level high signal [V] | 11 |
Digital inputs protected against short circuits | yes |
Outputs |
---|
Electrical design | AS-i |
Number of pneumatic outputs | 2 |
Operating conditions |
---|
Ambient temperature [°C] | -10…50 |
Protection | IP 50 |
AS-i classification |
---|
AS-i version | 2.11; 3.0 |
AS-i addressing | addressing socket |
Extended addressing mode possible | yes |
AS-i profile | S-7.A.E |
AS-i I/O configuration [hex] | 7 |
AS-i ID code [hex] | A.E |
AS-i certificate pending | yes |
Assignment of the data bits | data bit | D0 | D1 | D2 | D3 | input | 1 | 2 | 3 | 4 | socket | I-1/2 | I-1/2 I-2 | I-3/4 | I-3/4 I-4 | pin | 4 | 2 4 | 4 | 2 4 | pneumatic output | 2 | 4 | – | – |
|
Mechanical data |
---|
Weight [g] | 415.5 |
Type of mounting | quick mounting |
Materials | PA; POM; piercing contacts: CuSn6 nickel-plated and tin-plated |
Pneumatic system | 2 x 3/2-way slide valves (free from overlapping) |
Operating pressure range [bar] | 2…8 |
Operating pressure range [MPa] | 0.2…0.8 |
Air flow at 6/5 bar [l/min] | 500 |
Permissible compressed air | non-lubricated compressed air class 6-3-1; lubricated compressed air class 6-3-4 |
Manual override | pressing/releasing or pressing/turning/locking |
Tube fittings | 8 mm |
Exhaust | exhaust can be discharged through tube connection |
Displays / operating elements |
---|
Display | operation | LED, green | errors | LED, red | function | LED, yellow |
|
Accessories |
---|
Accessories (supplied) | |
Accessories (optional) | Mounting plate:, E74999 | Module lower part:, E75000 | Protective cap: M12, E73004 | sealing plugs:, E75231 | Impact protection housing:, E7000A | silencer:, E75232 | Push-in L-fitting:, E75228 | Push-in T-fitting:, E75227 |
|
Remarks |
---|
Remarks | Mechanical protection has to be implemented. | Otherwise the unit must be installed together with the impact protection housing (E7000A). | If not pneumatically operated, E75231 sealing plug must be inserted. | Avoid ingress of dirt and dust. | Do not connect any of the following points to an external potential: | L-, L+, I-1, I-2, I-3, I-4 | The connections are electrically connected with the AS-i cable. | Please see the notes on compressed air and EMC/ESD under “Downloads” |
|
Pack quantity | 1 pcs. |
Electrical connection |
---|
Connection | quick mounting technology for AS-i flat cable: ; three orientations possible |
Connection | Connector: M12 |