Product characteristics | |||||||||
---|---|---|---|---|---|---|---|---|---|
Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 | ||||||||
Factory setting | hydrous coolants; water; media similar to water | ||||||||
Probe length L [mm] | 472 | ||||||||
Application | |||||||||
Special feature | Gold-plated contacts | ||||||||
Media | hydrous coolants; oils; oil-based media; water; media similar to water | ||||||||
Dielectric constant of the medium | > 2 | ||||||||
Cannot be used for | extremely conductive media; adhering media; granulates; bulk material; acids; alkali; food and electroplating industry | ||||||||
Maximum speed of the change of level [mm/s] | 200 | ||||||||
Tank pressure [bar] | 0.5; (when mounting with mounting accessories: E43001 – E43007, E43019) | ||||||||
Coolants | |||||||||
Medium temperature [°C] | 0…35; (with climatic tube E43101: 35…60 °C) | ||||||||
Oil | |||||||||
Medium temperature [°C] | 0…70 | ||||||||
Medium temperature short time [°C] | 0…90; (< 1 h) | ||||||||
Water | |||||||||
Medium temperature [°C] | 0…35; (with climatic tube E43101: 35…60 °C) | ||||||||
Electrical data | |||||||||
Operating voltage [V] | 18…30 DC | ||||||||
Current consumption [mA] | < 50 | ||||||||
Protection class | III | ||||||||
Reverse polarity protection | yes | ||||||||
Power-on delay time [s] | < 3 | ||||||||
Inputs / outputs | |||||||||
Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 | ||||||||
Outputs | |||||||||
Total number of outputs | 2 | ||||||||
Output signal | switching signal; analogue signal; IO-Link | ||||||||
Electrical design | PNP/NPN | ||||||||
Number of digital outputs | 1 | ||||||||
Output function | normally open / normally closed; (parameterisable) | ||||||||
Max. voltage drop switching output DC [V] | 2.5 | ||||||||
Permanent current rating of switching output DC [mA] | 200 | ||||||||
Number of analogue outputs | 1 | ||||||||
Analogue current output [mA] | 4…20, invertible | ||||||||
Max. load [Ω] | 500 | ||||||||
Analogue voltage output [V] | 0…10, invertible | ||||||||
Min. load resistance [Ω] | 2000 | ||||||||
Short-circuit protection | yes | ||||||||
Type of short-circuit protection | thermal, pulsed | ||||||||
Overload protection | yes | ||||||||
Measuring/setting range | |||||||||
Factory setting | hydrous coolants; water; media similar to water | ||||||||
Probe length L [mm] | 472 | ||||||||
Active range A [mm] | 390 | ||||||||
Inactive range I1 / I2 [mm] | 60 / 22 | ||||||||
Setting range | |||||||||
Set point SP [mm] | 35…390 | ||||||||
Reset point rP [mm] | 30…385 | ||||||||
Hysteresis [mm] | 5 | ||||||||
Reference point OP [mm] | 139 – 163 – 188 – 212 – 236 – 261 – 285 – 310 – 334 – 358 – 383 – 407 – OFF | ||||||||
Hysteresis, OP [mm] | 3 | ||||||||
Accuracy / deviations | |||||||||
Measuring error [% of the final value] | ± 5 | ||||||||
Repeatability | ± 2 | ||||||||
Resolution [mm] | 5 | ||||||||
Zero signal (voltage) [V] | 0 | ||||||||
Zero signal (current) [mA] | 4.0 | ||||||||
Full signal (voltage) [V] | 10 | ||||||||
Full signal (current) [mA] | 20 | ||||||||
Software / programming | |||||||||
Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; current/voltage output; SP/rP position; adjustment OP; medium selection; offset setting; switch-on/switch-off delay | ||||||||
Interfaces | |||||||||
Communication interface | IO-Link | ||||||||
Transmission type | COM2 (38,4 kBaud) | ||||||||
IO-Link revision | 1.1 | ||||||||
SDCI standard | IEC 61131-9 | ||||||||
Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | ||||||||
SIO mode | yes | ||||||||
Required master port type | A | ||||||||
Process data analogue | 2 | ||||||||
Process data binary | 1 | ||||||||
Min. process cycle time [ms] | 3.2 | ||||||||
Supported DeviceIDs |
| ||||||||
Operating conditions | |||||||||
Ambient temperature [°C] | 0…60 | ||||||||
Storage temperature [°C] | -25…80 | ||||||||
Protection | IP 67 | ||||||||
Mechanical data | |||||||||
Weight [g] | 442 | ||||||||
Dimensions [mm] | Ø 16 | ||||||||
Materials | stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; NBR; PBT; PC; PA; PP; TPV | ||||||||
Materials (wetted parts) | PP | ||||||||
Displays / operating elements | |||||||||
Display |
| ||||||||
Remarks | |||||||||
Notes | Please see the technical note under “Downloads” | ||||||||
Pack quantity | 1 pcs. | ||||||||
Electrical connection | |||||||||
Connection | Connector: 1 x M12; Contacts: gold-plated |
Cảm biến mức IFM LK3123
19.819.000 ₫
SKU: LK3123
Hãng sản xuất: IFM
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng từ: CO/CQ, hóa đơn VAT
Khu vực Miền Nam
Khu vực Miền Bắc
Khu vực Miền Trung
Dịch vụ kỹ thuật/Bảo hành
Email liên hệ
Dịch vụ cung ứng sản phẩm
Vì sản phẩm đa dạng, nếu Quý khách chưa tìm được. Vui lòng liên hệ để được hỗ trợ.
Tư vấn lựa chọn hoặc chuyển đổi
Nhập khẩu thiết bị theo yêu cầu