| Product characteristics | 
|---|
| Number of inputs and outputs | Number of digital outputs: 2 | 
| Factory setting | hydrous media | 
| Process connection | threaded connection G 1/2 sealing cone | 
| Application | 
|---|
| Special feature | Gold-plated contacts | 
| Media | Liquids; viscous media; powder | 
| Cannot be used for | See the operating instructions, chapter “Function and features”. | 
| Probe length [mm] | 11 | 
| Tank pressure [bar] | -1…40 | 
| MAWP (for applications according to CRN) [bar] | 40 | 
| Oil | 
|---|
| Medium temperature [°C] | -40…100 | 
| Medium temperature short time [°C] | -40…150; (1 h) | 
| Water | 
|---|
| Medium temperature [°C] | -40…100 | 
| Medium temperature short time [°C] | -40…150; (1 h) | 
| Electrical data | 
|---|
| Operating voltage [V] | 18…30 DC | 
| Current consumption [mA] | < 50 | 
| Protection class | III | 
| Reverse polarity protection | yes | 
| Inputs / outputs | 
|---|
| Number of inputs and outputs | Number of digital outputs: 2 | 
| Outputs | 
|---|
| Total number of outputs | 2 | 
| Output signal | switching signal; IO-Link | 
| Electrical design | PNP/NPN | 
| Number of digital outputs | 2 | 
| Output function | normally open / normally closed; (parameterisable) | 
| Max. voltage drop switching output DC [V] | 2.5 | 
| Permanent current rating of switching output DC [mA] | 100 | 
| Short-circuit protection | yes | 
| Type of short-circuit protection | pulsed | 
| Overload protection | yes | 
| Measuring/setting range | 
|---|
| Factory setting | hydrous media | 
| Response times | 
|---|
| Response time [s] | < 0.5 | 
| Interfaces | 
|---|
| Communication interface | IO-Link | 
| Transmission type | COM2 (38,4 kBaud) | 
| IO-Link revision | 1.1 | 
| SDCI standard | IEC 61131-9 | 
| Profiles | Smart Sensor: Process Data Variable; Device Identification | 
| SIO mode | yes | 
| Required master port type | A | 
| Process data analogue | 1 | 
| Process data binary | 2 | 
| Min. process cycle time [ms] | 2.3 | 
| Supported DeviceIDs | | Type of operation | DeviceID |  | Default | 304 | 
 | 
| Operating conditions | 
|---|
| Ambient temperature [°C] | -40…85 | 
| Note on ambient temperature | | Medium temperature: < 100 °C |  | -40…60 °C |  | Medium temperature: < 150 °C | 
 | 
| Storage temperature [°C] | -40…85 | 
| Protection | IP 68; IP 69K | 
| Mechanical data | 
|---|
| Weight [g] | 208.5 | 
| Materials | stainless steel (1.4404 / 316L); PEEK; PEI; FKM | 
| Materials (wetted parts) | PEEK; surface characteristics : Ra < 0,8 / Rz 4 | 
| Process connection | threaded connection G 1/2 sealing cone | 
| Displays / operating elements | 
|---|
| Display | | switching status | LED, yellow |  | operating status | LED, green | 
 | 
| Remarks | 
|---|
| Pack quantity | 1 pcs. | 
| Electrical connection | 
|---|
| Connection | Connector: 1 x M12; Contacts: gold-plated |