| Product characteristics |
|---|
| Number of inputs and outputs | Number of digital outputs: 2 |
| Factory setting | media with low water content |
| Process connection | threaded connection G 1/2 sealing cone |
| Application |
|---|
| Special feature | Gold-plated contacts |
| Media | Liquids; viscous media; powder |
| Cannot be used for | See the operating instructions, chapter “Function and features”. |
| Probe length [mm] | 11 |
| Tank pressure [bar] | -1…40; (MAWP (for applications according to CRN): 40 bar / 4 MPa) |
| MAWP (for applications according to CRN) [bar] | 40 |
| Oil |
|---|
| Medium temperature [°C] | -40…100 |
| Medium temperature short time [°C] | -40…150; (1 h) |
| Water |
|---|
| Medium temperature [°C] | -40…100 |
| Medium temperature short time [°C] | -40…150; (1 h) |
| Electrical data |
|---|
| Operating voltage [V] | 18…30 DC |
| Current consumption [mA] | < 50 |
| Protection class | III |
| Reverse polarity protection | yes |
| Inputs / outputs |
|---|
| Number of inputs and outputs | Number of digital outputs: 2 |
| Outputs |
|---|
| Total number of outputs | 2 |
| Output signal | switching signal; IO-Link |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] | 2.5 |
| Permanent current rating of switching output DC [mA] | 100 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
| Measuring/setting range |
|---|
| Factory setting | media with low water content |
| Response times |
|---|
| Response time [s] | < 0.5 |
| Interfaces |
|---|
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor: Process Data Variable; Device Identification |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 1 |
| Process data binary | 2 |
| Min. process cycle time [ms] | 2.3 |
| Supported DeviceIDs | | Type of operation | DeviceID | | Default | 306 |
|
| Operating conditions |
|---|
| Ambient temperature [°C] | -40…85 |
| Note on ambient temperature | | Medium temperature: < 100 °C | | -40…60 °C | | Medium temperature: < 150 °C |
|
| Storage temperature [°C] | -40…85 |
| Protection | IP 68; IP 69K |
| Mechanical data |
|---|
| Weight [g] | 211 |
| Materials | stainless steel (1.4404 / 316L); PEEK; PEI; FKM |
| Materials (wetted parts) | PEEK; surface characteristics : Ra < 0,8 / Rz 4 |
| Process connection | threaded connection G 1/2 sealing cone |
| Displays / operating elements |
|---|
| Display | | switching status | LED, yellow | | operating status | LED, green |
|
| Remarks |
|---|
| Pack quantity | 1 pcs. |
| Electrical connection |
|---|
| Connection | Connector: 1 x M12; Contacts: gold-plated |