Product characteristics |
---|
Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
Probe length L [mm] | 150…2000 |
Process connection | G 3/4 external thread |
Application |
---|
Special feature | Gold-plated contacts |
Media | Liquids; oil-based media; hydrous media |
Dielectric constant of the medium | ≥ 1,8; (for media with a dielectric constant of 1.8…5 (e.g. oils), a coaxial pipe is needed for operation) |
Recommended media | water; hydrous media; oils; oil-based media |
Medium temperature [°C] | -20…100 |
Tank pressure [bar] | -1…16 |
MAWP (for applications according to CRN) [bar] | 16 |
Electrical data |
---|
Operating voltage [V] | 18…30 DC |
Current consumption [mA] | < 50 |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | < 3 |
Inputs / outputs |
---|
Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
Outputs |
---|
Total number of outputs | 2 |
Output signal | switching signal; analogue signal; IO-Link |
Electrical design | PNP/NPN |
Number of digital outputs | 1 |
Output function | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] | 2.5 |
Permanent current rating of switching output DC [mA] | 150; (200 (…60 °C)) |
Number of analogue outputs | 1 |
Analogue current output [mA] | 4…20, invertible; (scalable) |
Max. load [Ω] | 500 |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Measuring/setting range |
---|
Probe length L [mm] | 150…2000 |
Active range A [mm] | L-40 (L-60); (when set to oil and oil based media) |
Inactive range I1 / I2 [mm] | 30 / 10 (30); (when set to oil and oil based media) |
Sampling rate [Hz] | 4 |
Setting range |
---|
Set point SP [mm] | ≥ 15 (35) / ≤ L-30 |
Note on setpoint SP | when set to oil and oil based media |
|
Reset point rP [mm] | ≥ 10 (30) / ≤ L-35 |
Note on reset point rP | when set to oil and oil based media |
|
In steps of [mm] | 1 |
Hysteresis [mm] | > 5 |
Accuracy / deviations |
---|
Measuring error [mm] | ± 7 |
Offset error [mm] | 5 |
Resolution [mm] | 1 |
Zero signal (current) [mA] | 4.0 |
Full signal (current) [mA] | 20 |
Temperature drift per 10 K | ± 0.2 % |
Interfaces |
---|
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
SDCI standard | IEC 61131-9 |
Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO mode | yes |
Required master port type | A |
Process data analogue | 1 |
Process data binary | 2 |
Min. process cycle time [ms] | 2.3 |
Supported DeviceIDs | Type of operation | DeviceID | Default | 479 |
|
Operating conditions |
---|
Ambient temperature [°C] | -40…80 |
Storage temperature [°C] | -40…100 |
Protection | IP 68; IP 69K |
Mechanical data |
---|
Weight [g] | 447.5 |
Materials | stainless steel (1.4404 / 316L); PEI; PFA; PBT; FKM |
Materials (wetted parts) | stainless steel (1.4404 / 316L); stainless steel (1.4435 / 316L); PTFE; FKM |
Process connection | G 3/4 external thread |
Displays / operating elements |
---|
Display | Display unit | 3 x LED, green | switching status | 2 x LED, yellow | level | alphanumeric display, 4-digit | parameter setting | alphanumeric display, 4-digit |
|
Remarks |
---|
Pack quantity | 1 pcs. |
Electrical connection |
---|
Connection | Connector: 1 x M12; Contacts: gold-plated |