|  Product characteristics | 
|---|
|  Number of inputs and outputs |  Number of digital outputs: 2 | 
|  Probe length L [mm] |  100…1600 | 
|  Process connection |  3/4″ NPT | 
|  Application | 
|---|
|  Special feature |  Gold-plated contacts | 
|  Media |  Liquids | 
|  Dielectric constant of the medium |  ≥ 5 | 
|  Recommended media |  water; hydrous media | 
|  Cannot be used for |  See the operating instructions, chapter “Function and features”. | 
|  Medium temperature [°C] |  -25…80; (90 < 1 h) | 
|  Tank pressure [bar] |  -1…16 | 
|  MAWP (for applications according to CRN) [bar] |  16 | 
|  Electrical data | 
|---|
|  Operating voltage [V] |  18…30 DC | 
|  Current consumption [mA] |  < 30 | 
|  Protection class |  III | 
|  Reverse polarity protection |  yes | 
|  Power-on delay time [s] |  < 3 | 
|  Inputs / outputs | 
|---|
|  Number of inputs and outputs |  Number of digital outputs: 2 | 
|  Outputs | 
|---|
|  Total number of outputs |  2 | 
|  Output signal |  switching signal; IO-Link | 
|  Electrical design |  PNP | 
|  Number of digital outputs |  2 | 
|  Output function |  normally open / normally closed; (parameterisable) | 
|  Max. voltage drop switching output DC [V] |  2.5 | 
|  Permanent current rating of switching output DC [mA] |  200 | 
|  Short-circuit protection |  yes | 
|  Type of short-circuit protection |  thermal, pulsed | 
|  Overload protection |  yes | 
|  Measuring/setting range | 
|---|
|  Probe length L [mm] |  100…1600 | 
|  Active range A [mm] |  L-40 | 
|  Inactive range I1 / I2 [mm] |  30 / 10 | 
|  Sampling rate [Hz] |  4 | 
|  Setting range | 
|---|
|  Set point SP [mm] |  ≥ 15…L-30 | 
|  Reset point rP [mm] |  ≥ 10…L-35 | 
|  In steps of [mm] |  5 | 
|  Hysteresis [mm] |  > 5 | 
|  Accuracy / deviations | 
|---|
|  Repeatability [mm] |  ± 5 | 
|  Measuring error [mm] |  ± 7 | 
|  Offset error [mm] |  5 | 
|  Resolution [mm] |  1 | 
|  Temperature drift per 10 K |  ± 0.2 % | 
|  Interfaces | 
|---|
|  Communication interface |  IO-Link | 
|  Transmission type |  COM2 (38,4 kBaud) | 
|  IO-Link revision |  1.1 | 
|  SDCI standard |  IEC 61131-9 CDV | 
|  Profiles |  no profile | 
|  SIO mode |  yes | 
|  Required master port type |  A | 
|  Process data analogue |  1 | 
|  Process data binary |  2 | 
|  Min. process cycle time [ms] |  2.3 | 
|  Supported DeviceIDs | |  Type of operation |  DeviceID |  |  Default |  9 |  
  | 
|  Operating conditions | 
|---|
|  Ambient temperature [°C] |  -25…60 | 
|  Storage temperature [°C] |  -40…85 | 
|  Protection |  IP 67 | 
|  Mechanical data | 
|---|
|  Weight [g] |  344.5 | 
|  Materials |  stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L) ; FKM; PBT; PC; PEI; TPE-V | 
|  Materials (wetted parts) |  stainless steel (1.4305 / 303); probe connection: stainless steel (1.4435 / 316L); PTFE; FKM | 
|  Process connection |  3/4″ NPT | 
|  Displays / operating elements | 
|---|
|  Display | |  Display unit |  3 x LED, green |  |  switching status |  2 x LED, yellow |  |  level |  alphanumeric display, 4-digit |  |  parameter setting |  alphanumeric display, 4-digit |  
  | 
|  Remarks | 
|---|
|  Notes |  Please see the technical note under “Downloads” | 
|  Pack quantity |  1 pcs. | 
|  Electrical connection | 
|---|
|  Connection |  Connector: 1 x M12; Contacts: gold-plated |