| Product characteristics |
|---|
| Number of inputs and outputs | Number of digital outputs: 4 |
| Probe length L [mm] | 100…1600 |
| Process connection | G 3/4 external thread |
| Application |
|---|
| Special feature | Gold-plated contacts |
| Installation | Operation only in conjunction with rod and coaxial pipe. |
| Media | hydrous coolants; oils; oil-based media; water; media similar to water |
| Dielectric constant of the medium | ≥ 2 |
| Cannot be used for | See the operating instructions, chapter “Function and features”. |
| Medium temperature [°C] | 0…80 |
| Tank pressure [bar] | -0.5…4 |
| Electrical data |
|---|
| Operating voltage [V] | 18…30 DC |
| Current consumption [mA] | < 65 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | < 3 |
| Inputs / outputs |
|---|
| Number of inputs and outputs | Number of digital outputs: 4 |
| Outputs |
|---|
| Total number of outputs | 4 |
| Output signal | switching signal |
| Electrical design | PNP |
| Number of digital outputs | 4 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] | 2.5 |
| Permanent current rating of switching output DC [mA] | 200 |
| Short-circuit protection | yes |
| Type of short-circuit protection | thermal, pulsed |
| Overload protection | yes |
| Measuring/setting range |
|---|
| Probe length L [mm] | 100…1600 |
| Active range A [mm] | L-40 (L-60); (when set to oil and oil based media) |
| Inactive range I1 / I2 [mm] | 30 / 10 (30); (when set to oil and oil based media) |
| Setting range |
|---|
| Set point SP [mm] | ≥ 15 (35) / ≤ L-30 |
| Note on setpoint SP | | when set to oil and oil based media |
|
| Reset point rP [mm] | ≥ 10 (30) / ≤ L-35 |
| Note on reset point rP | | when set to oil and oil based media |
|
| In steps of [mm] | 5 |
| Hysteresis [mm] | > 5 |
| Overflow switch point OP [mm] | 70…L-30 |
| Hysteresis, OP [mm] | 10 |
| Accuracy / deviations |
|---|
| Repeatability [mm] | ± 5 |
| Switch point accuracy [mm] | ± (15 + 0,5 % ); (% of the final value of the measuring range: L – 30 mm) |
| Operating conditions |
|---|
| Ambient temperature [°C] | 0…60 |
| Storage temperature [°C] | -25…80 |
| Protection | IP 67 |
| Mechanical data |
|---|
| Weight [g] | 402 |
| Materials | stainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); FKM; PBT-GF20; PC; PEI; TPV |
| Materials (wetted parts) | stainless steel (1.4305 / 303); probe connection: stainless steel (1.4435 / 316L); PTFE; FKM; Sealing: NBR-PPTA 20 |
| Process connection | G 3/4 external thread |
| Displays / operating elements |
|---|
| Display | | Display unit | 3 x LED, green | | switching status | 4 x LED, yellow | | level | alphanumeric display, 4-digit | | parameter setting | alphanumeric display, 4-digit |
|
| Remarks |
|---|
| Notes | For 8-pole sockets the core colours are not standardised.; Please note the wiring of the sensor and the sockets (see data sheet). |
| Pack quantity | 1 pcs. |
| Electrical connection |
|---|
| Connection | Connector: 1 x M12; Contacts: gold-plated |