| Product characteristics | |||||
|---|---|---|---|---|---|
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 | ||||
| Probe length L [mm] | 100…1600 | ||||
| Process connection | G 3/4 external thread | ||||
| Application | |||||
| Special feature | Gold-plated contacts | ||||
| Media | Liquids | ||||
| Dielectric constant of the medium | ≥ 1,8; (for media with a dielectric constant of 1.8…5 (e.g. oils), a coaxial pipe is needed for operation) | ||||
| Recommended media | water; hydrous media; oils; oil-based media | ||||
| Cannot be used for | See the operating instructions, chapter “Function and features”. | ||||
| Medium temperature [°C] | -25…80; (90 < 1 h) | ||||
| Tank pressure [bar] | -1…16 | ||||
| MAWP (for applications according to CRN) [bar] | 16 | ||||
| Electrical data | |||||
| Operating voltage [V] | 18…30 DC | ||||
| Current consumption [mA] | < 25 | ||||
| Protection class | III | ||||
| Reverse polarity protection | yes | ||||
| Power-on delay time [s] | < 3 | ||||
| Inputs / outputs | |||||
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 | ||||
| Outputs | |||||
| Total number of outputs | 2 | ||||
| Output signal | analogue signal; IO-Link | ||||
| Electrical design | PNP | ||||
| Number of digital outputs | 1 | ||||
| Number of analogue outputs | 1 | ||||
| Analogue current output [mA] | 4…20, invertible | ||||
| Max. load [Ω] | 500 | ||||
| Analogue voltage output [V] | 0…10, invertible | ||||
| Min. load resistance [Ω] | 2000 | ||||
| Short-circuit protection | yes | ||||
| Type of short-circuit protection | thermal, pulsed | ||||
| Overload protection | yes | ||||
| Measuring/setting range | |||||
| Probe length L [mm] | 100…1600 | ||||
| Active range A [mm] | L-40; (when set to oil and oil based media: L-60) | ||||
| Inactive range I1 / I2 [mm] | 30 / 10; (when set to oil and oil based media: 30 / 30) | ||||
| Sampling rate [Hz] | 4 | ||||
| Accuracy / deviations | |||||
| Repeatability [mm] | ± 5 | ||||
| Measuring error [mm] | ± 7 | ||||
| Offset error [mm] | 5 | ||||
| Resolution [mm] | 1 | ||||
| Zero signal (voltage) [V] | 0 | ||||
| Zero signal (current) [mA] | 4 | ||||
| Full signal (voltage) [V] | 10 | ||||
| Full signal (current) [mA] | 20 | ||||
| Temperature drift per 10 K | ± 0.2 % | ||||
| Interfaces | |||||
| Communication interface | IO-Link | ||||
| Transmission type | COM2 (38,4 kBaud) | ||||
| IO-Link revision | 1.1 | ||||
| SDCI standard | IEC 61131-9 CDV | ||||
| Profiles | no profile | ||||
| SIO mode | no | ||||
| Required master port type | A | ||||
| Process data analogue | 1 | ||||
| Min. process cycle time [ms] | 2.3 | ||||
| Supported DeviceIDs |
| ||||
| Operating conditions | |||||
| Ambient temperature [°C] | -25…60 | ||||
| Storage temperature [°C] | -40…85 | ||||
| Protection | IP 68; IP 69K; (7 days / 1 m water depth / 0.1 bar: IP 68) | ||||
| Mechanical data | |||||
| Weight [g] | 430 | ||||
| Materials | stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; PEI | ||||
| Materials (wetted parts) | stainless steel (1.4305 / 303); probe connection: stainless steel (1.4435 / 316L); PTFE; FKM; Sealing: NBR reinforced fibre | ||||
| Process connection | G 3/4 external thread | ||||
| Remarks | |||||
| Notes | Please see the technical note under “Downloads” | ||||
| Pack quantity | 1 pcs. | ||||
| Electrical connection | |||||
| Connection | Connector: 1 x M12; Contacts: gold-plated | ||||
Cảm biến mức IFM LR9020
9.520.000 ₫
SKU: LR9020
Hãng sản xuất: IFM
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng từ: CO/CQ, hóa đơn VAT