Product characteristics |
---|
Output function | 2 x normally open; (potentialfrei) |
Sensing range [mm] | 8; (with defined actuator) |
Housing | rectangular |
Dimensions [mm] | 88 x 13.1 x 25 |
Application |
---|
Design | coded target |
Type of operation | permanent operation |
Application | for safety-related applications |
Electrical data |
---|
Operating voltage [V] | 24 DC |
Rated insulation voltage [V] | 60 |
Protection class | III |
Reverse polarity protection | no |
Internal resistance (Ri) [Ω] | 10; (1 W) |
Outputs |
---|
Output function | 2 x normally open; (potentialfrei) |
Permanent current rating of switching output DC [mA] | 50 |
Switching frequency DC [Hz] | 150 |
Output data | Interface type A |
Short-circuit proof | no |
Max. capacitive load CL_max [nF] | 20 |
Detection zone |
---|
Sensing range [mm] | 8; (with defined actuator) |
Safe switching-off distance s(ar) [mm] | 20 |
Response times |
---|
Response time to safety request [ms] | 10 |
Max. fall time [ms] | 0.1 |
Max. make time incl. bounce [ms] | 0.6 |
Operating conditions |
---|
Applications | class C to EN 60654-1 weatherproof application |
Ambient temperature [°C] | -25…80 |
Note on ambient temperature | operational life ≤ 87600 h |
|
Ambient temperature [°C] | 10…40 |
Note on ambient temperature | operational life ≤ 175200 h |
|
Max. relative air humidity [%] | briefly: 5…95 %; permanent: 5…70 % |
Air pressure [kPa] | 80…106 |
Max. height above sea level [m] | 2000 |
Salt spray | no |
Protection | IP 67; IP 69K; (protected cable laying) |
Safety classification |
---|
Mission time TM [h] | ≤ 175200 |
Mission time TM (additional indication) | |
B10D | 20.000.000; (without load; at max. load DC 12, 24 V, 50 mA : 400.000) |
Mechanical data |
---|
Weight [g] | 174.5 |
Housing | rectangular |
Mounting | non-flush mountable |
Dimensions [mm] | 88 x 13.1 x 25 |
Materials | housing: PA; mounting plate: stainless steel (1.4301 / 304) |
Tightening torque [Nm] | 0.8…2 |
Accessories |
---|
Accessories (supplied) | |
Remarks |
---|
Remarks | In connection with a G150xS / AC4x2S type evaluation unit, it is possible to reach up to PL e (ISO 13849-1) or SIL cl 3 (IEC 62061) |
|
Pack quantity | 1 pcs. |
Electrical connection – plug |
---|
Connection | Cable: 0.1 m, PVC, Ø 5 mm |
Connection | Connector: 1 x M12 |