|  Product characteristics | 
|---|
|  Communication interface |  IO-Link | 
|  Laser protection class |  2 | 
|  Housing |  rectangular | 
|  Dimensions [mm] |  59 x 42 x 52 | 
|  Electrical data | 
|---|
|  Operating voltage [V] |  18…30 DC; (operating voltage “supply class 2” according to cULus) | 
|  Current consumption [mA] |  < 150 | 
|  Protection class |  III | 
|  Reverse polarity protection |  yes | 
|  Typ. lifetime [h] |  50000 | 
|  Inputs / outputs | 
|---|
|  Number of inputs and outputs |  Number of digital outputs: 2; Number of analogue outputs: 1 | 
|  Outputs | 
|---|
|  Total number of outputs |  2 | 
|  Electrical design |  PNP | 
|  Number of digital outputs |  2 | 
|  Output function |  normally open / normally closed; (parameterisable) | 
|  Max. current load per output [mA] |  200 | 
|  Number of analogue outputs |  1 | 
|  Analogue current output [mA] |  4…20; (IEC 61131-2) | 
|  Max. load [Ω] |  250 | 
|  Analogue voltage output [V] |  0…10; (IEC 61131-2) | 
|  Min. load resistance [Ω] |  5000 | 
|  Short-circuit protection |  yes | 
|  Type of short-circuit protection |  pulsed | 
|  Overload protection |  yes | 
|  Detection zone | 
|---|
|  Max. light spot width [mm] |  15 | 
|  Max. light spot height [mm] |  15 | 
|  Light spot dimensions refer to |  10 m | 
|  Background suppression [m] |  0…19 | 
|  Measuring/setting range | 
|---|
|  Measuring range [m] |  0.2…10; (white paper 200 x 200 mm 90% remission) | 
|  Sampling rate [Hz] |  1…50 | 
|  Interfaces | 
|---|
|  Communication interface |  IO-Link | 
|  Transmission type |  COM2 (38,4 kBaud) | 
|  IO-Link revision |  1.1 | 
|  SDCI standard |  IEC 61131-9 | 
|  Profiles |  Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis | 
|  SIO mode |  yes | 
|  Required master port type |  A | 
|  Process data analogue |  2 | 
|  Process data binary |  2 | 
|  Min. process cycle time [ms] |  6 | 
|  Supported DeviceIDs | |  Type of operation |  DeviceID |  |  Default |  806 |  
  | 
|  Operating conditions | 
|---|
|  Ambient temperature [°C] |  -10…60 | 
|  Protection |  IP 67 | 
|  Mechanical data | 
|---|
|  Weight [g] |  308.5 | 
|  Housing |  rectangular | 
|  Dimensions [mm] |  59 x 42 x 52 | 
|  Materials |  housing: diecast zinc; front lens: glass; LED window: PC | 
|  Lens alignment |  side lens | 
|  Displays / operating elements | 
|---|
|  Display | |  switching status |  2 x LED, yellow |  |  operation |  LED, green |  |  distance value, programming |  alphanumeric display, 4-digit |  
  | 
|  Accessories | 
|---|
|  Accessories (optional) |  | 
|  Remarks | 
|---|
|  Remarks | |  For more information about the measuring range / application please refer to the operating instructions. |  
  | 
|  Pack quantity |  1 pcs. | 
|  Electrical connection | 
|---|
|  Connection |  Connector: 1 x M12 |