| Product characteristics |
|---|
| Communication interface | IO-Link |
| Laser protection class | 2 |
| Housing | rectangular |
| Dimensions [mm] | 59 x 42 x 52 |
| Application |
|---|
| Application [m] | 0.2…100 |
| Electrical data |
|---|
| Operating voltage [V] | 18…30 DC; (“supply class 2” to cULus) |
| Current consumption [mA] | < 150 |
| Protection class | III |
| Reverse polarity protection | yes |
| Typ. lifetime [h] | 50000 |
| Inputs / outputs |
|---|
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Outputs |
|---|
| Total number of outputs | 2 |
| Electrical design | PNP |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (programmable) |
| Max. current load per output [mA] | 200 |
| Number of analogue outputs | 1 |
| Analogue current output [mA] | 4…20; (IEC 61131-2) |
| Max. load [Ω] | 250 |
| Analogue voltage output [V] | 0…10; (IEC 61131-2) |
| Min. load resistance [Ω] | 5000 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
| Detection zone |
|---|
| Max. light spot width [mm] | 25 |
| Max. light spot height [mm] | 25 |
| Light spot dimensions refer to | 18 m |
| Background suppression [m] | < 100 |
| Measuring/setting range |
|---|
| Measuring range [m] | 0.2…18; (white paper 200 x 200 mm 90% remission) |
| Sampling rate [Hz] | 1…33 |
| Interfaces |
|---|
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 2 |
| Process data binary | 2 |
| Min. process cycle time [ms] | 6 |
| Supported DeviceIDs | | Type of operation | DeviceID | | Default | 811 |
|
| Operating conditions |
|---|
| Ambient temperature [°C] | -10…60 |
| Protection | IP 67 |
| Mechanical data |
|---|
| Weight [g] | 300.2 |
| Housing | rectangular |
| Dimensions [mm] | 59 x 42 x 52 |
| Materials | housing: diecast zinc; front lens: glass; LED window: PC |
| Lens alignment | side lens |
| Displays / operating elements |
|---|
| Display | | switching status | 2 x LED, yellow | | operation | LED, green | | distance value, programming | alphanumeric display, 4-digit |
|
| Accessories |
|---|
| Accessories (optional) | |
| Remarks |
|---|
| Pack quantity | 1 pcs. |
| Electrical connection |
|---|
| Connection | Connector: 1 x M12 |
| Other data |
|---|
| Parameter | Setting range | Factory setting | | Uni | m, inch | m | | OU1 | Hno, Hnc, Fno, Fnc | Hno | | SP1 | 0.20…18.00 | 1.00 | | nSP1 | 0.20…18.00 | 0.80 | | FSP1 | 0.20…18.00 | 1.20 | | OU2 | Hno, Hnc, Fno, Fnc, I, U | I | | SP2 | 0.20…18.00 | 2.00 | | nSP2 | 0.20…18.00 | 1.80 | | FSP2 | 0.20…18.00 | 2.20 | | ASP | 0…18.00 | 0 | | AEP | 0…18.00 | 18.00 | | rATE [Hz] | 1…33 | 15 | | dS1 | 0…0.1…5 | 0 | | dr1 | 0…0.1…5 | 0 | | dS2 | 0…0.1…5 | 0 | | dr2 | 0…0.1…5 | 0 | | dFo | 0…0.1…5 | 0 | | dIS | d1…3 ; rd1…3; OFF | d3 |
|
| repeatability/accuracy |
|---|
| repeatability of the measured values | | Accuracy | | | white (90 % remission) | grey (18 % remission) | white (90 % remission) | grey (18 % remission) | | 0.20…1.0 m | ± 0.45 cm | ± 0.6 cm | ± 1.5 cm | ± 1.6 cm | | 1.00…2.00 m | ± 0.5 cm | ± 0.8 cm | ± 1.5 cm | ± 1.8 cm | | 2.00…4.00 m | ± 1.25 cm | ± 1.9 cm | ± 2.25 cm | ± 3.0 cm | | 4.00…6.00 m | ± 2.0 cm | ± 3.0 cm | ± 3.0 cm | ± 4.0 cm | | 6.00…10.00 m | ± 3.5 cm | ± 5.0 cm | ± 4.5 cm | ± 6.0 cm | | 10.00…18.00 m | ± 5.0 cm | | ± 6.0 cm | |
|
| Sampling rate | 15 Hz | | Extraneous light on the object | < 10 klx | | The values apply at | | | constant ambient conditions | 23 °C / 960 hPa | | minimum power-on time in minutes | 10 |
|
| repeatability/accuracy |
|---|
| repeatability of the measured values | | Accuracy | | | white (90 % remission) | grey (18 % remission) | white (90 % remission) | grey (18 % remission) | | 0.20…1.0 m | ± 0.45 cm | ± 0.6 cm | ± 1.5 cm | ± 1.6 cm | | 1.00…2.00 m | ± 0.5 cm | ± 0.8 cm | ± 1.5 cm | ± 1.8 cm | | 2.00…4.00 m | ± 1.6 cm | ± 1.9 cm | ± 2.5 cm | ± 3.0 cm | | 4.00…6.00 m | ± 2.4 cm | ± 3.3 cm | ± 3.5 cm | ± 4.5 cm | | 6.00…10.00 m | ± 5.0 cm | | ± 6.5 cm | |
|
| Sampling rate | 15 Hz | | Extraneous light on the object | < 40 klx | | The values apply at | | | constant ambient conditions | 23 °C / 960 hPa | | minimum power-on time in minutes | 10 |
|
| In case of higher extraneous light on the object (up to 40 klx) the following specifications apply: |
|---|
| white (90 % remission) | grey (18 % remission) | black (6 % remission) | | | Measuring range | 0.2…10 m | 0.2…6 m | 0.2…4 m | |
|