Product characteristics |
---|
Type of light | red light |
Communication interface | IO-Link |
Laser protection class | 1 |
Housing | rectangular |
Dimensions [mm] | 59 x 42 x 52 |
Electrical data |
---|
Operating voltage [V] | 18…30 DC |
Current consumption [mA] | < 150 |
Protection class | III |
Reverse polarity protection | yes |
Type of light | red light |
Wave length [nm] | 650 |
Typ. lifetime [h] | 50000 |
Inputs / outputs |
---|
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Outputs |
---|
Total number of outputs | 2 |
Electrical design | PNP |
Number of digital outputs | 2 |
Output function | normally open / normally closed; (programmable) |
Max. current load per output [mA] | 200 |
Number of analogue outputs | 1 |
Analogue current output [mA] | 4…20; (IEC 61131-2) |
Max. load [Ω] | 250 |
Analogue voltage output [V] | 0…10; (IEC 61131-2) |
Min. load resistance [Ω] | 5000 |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Detection zone |
---|
Max. light spot width [mm] | 8 |
Max. light spot height [mm] | 8 |
Light spot dimensions refer to | 6 m |
Background suppression [m] | 6…100 |
Measuring/setting range |
---|
Measuring range [m] | 0.3…6; (white paper 200 x 200 mm 90% remission) |
Sampling rate [Hz] | 1…33 |
Interfaces |
---|
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
SDCI standard | IEC 61131-9 |
Profiles | Smart Sensor: Sensor Identification; Binary Data Channel, Process Value; Sensor Diagnosis |
SIO mode | yes |
Required master port type | A |
Process data analogue | 2 |
Process data binary | 2 |
Min. process cycle time [ms] | 6 |
Supported DeviceIDs | Type of operation | DeviceID | Default | 812 |
|
Operating conditions |
---|
Ambient temperature [°C] | -10…60 |
Protection | IP 67 |
Mechanical data |
---|
Weight [g] | 310.5 |
Housing | rectangular |
Dimensions [mm] | 59 x 42 x 52 |
Materials | housing: diecast zinc; front lens: glass; LED window: PC |
Displays / operating elements |
---|
Display | switching status | 2 x LED, yellow | operation | LED, green | distance value, programming | alphanumeric display, 4-digit |
|
Accessories |
---|
Accessories (optional) | |
Remarks |
---|
Remarks | operating voltage “supply class 2” according to cULus |
|
Pack quantity | 1 pcs. |
Electrical connection |
---|
Connection | Connector: 1 x M12 |
Other data |
---|
Parameter | Setting range | Factory setting | Uni | mm, m, inch | mm | OU1 | Hno, Hnc, Fno, Fnc | Hno | SP1 | 300…5999 | 1000 | nSP1 | 300…5999 | 800 | FSP1 | 300…5999 | 1200 | OU2 | Hno, Hnc, Fno, Fnc, I, U | I | SP2 | 300…5999 | 2000 | nSP2 | 300…5999 | 1800 | FSP2 | 300…5999 | 2200 | ASP | 0…5999 | 0 | AEP | 0…5999 | 5999 | rATE [Hz] | 1…33 | 15 | dS1 | 0…0.1…5 | 0 | dr1 | 0…0.1…5 | 0 | dS2 | 0…0.1…5 | 0 | dr2 | 0…0.1…5 | 0 | dFo | 0…0.1…5 | 0 | dIS | d1…3 ; rd1…3; OFF | d3 |
|
repeatability/accuracy |
---|
| repeatability of the measured values | | Accuracy | | | white (90 % remission) | grey (18 % remission) | white (90 % remission) | grey (18 % remission) | 300…1000 mm | ± 11 mm | ± 13 mm | ± 31mm | ± 33 mm | 1000…2000 mm | ± 28 mm | ± 30 mm | ± 48 mm | ± 50 mm | 2000…3000 mm | ± 50 mm | ± 50 mm | ± 70 mm | ± 70 mm | 3000…4000 mm | ± 85 mm | ± 85 mm | ± 105 mm | ± 105 mm | 4000…5000 mm | ± 105 mm | | ± 125 mm | | 5000…6000 mm | ± 145 mm | | ± 165 mm | |
|
|
repeatability/accuracy |
---|
| repeatability of the measured values | | Accuracy | | | white (90 % remission) | grey (18 % remission) | white (90 % remission) | grey (18 % remission) | 300…1000 mm | ± 8 mm | ± 10 mm | ± 28 mm | ± 30 mm | 1000…2000 mm | ± 25 mm | ± 25 mm | ± 45 mm | ± 45 mm | 2000…3000 mm | ± 38 mm | ± 38 mm | ± 58 mm | ± 58 mm | 3000…4000 mm | ± 70 mm | ± 70 mm | ± 90 mm | ± 90 mm | 4000…5000 mm | ± 100 mm | | ± 120 mm | | 5000…6000 mm | ± 100 mm | | ± 120 mm | |
|
|
Range on black object (6 % remission) | <= 2500 klx | The values apply at | | Extraneous light on the object | < 100 klx | constant ambient conditions | 23 °C / 960 hPa | minimum power-on time in minutes | 10 |
|