| Product characteristics |
|---|
| Communication interface | IO-Link |
| Laser protection class | 2 |
| Housing | rectangular |
| Dimensions [mm] | 59 x 42 x 52 |
| Electrical data |
|---|
| Operating voltage [V] | 18…30 DC; (“supply class 2” to cULus) |
| Current consumption [mA] | < 150 |
| Protection class | III |
| Reverse polarity protection | yes |
| Typ. lifetime [h] | 50000 |
| Inputs / outputs |
|---|
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Outputs |
|---|
| Total number of outputs | 2 |
| Electrical design | PNP |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (programmable) |
| Max. current load per output [mA] | 200 |
| Number of analogue outputs | 1 |
| Analogue current output [mA] | 4…20; (IEC 61131-2) |
| Max. load [Ω] | 250 |
| Analogue voltage output [V] | 0…10; (IEC 61131-2) |
| Min. load resistance [Ω] | 5000 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
| Detection zone |
|---|
| Max. light spot width [mm] | 15 |
| Max. light spot height [mm] | 15 |
| Light spot dimensions refer to | 10 m |
| Background suppression [m] | 10…100 |
| Measuring/setting range |
|---|
| Measuring range [m] | 0.2…10; (white paper 200 x 200 mm 90% remission) |
| Sampling rate [Hz] | 1…33 |
| Interfaces |
|---|
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 2 |
| Process data binary | 2 |
| Min. process cycle time [ms] | 6 |
| Supported DeviceIDs | | Type of operation | DeviceID | | Default | 813 |
|
| Operating conditions |
|---|
| Ambient temperature [°C] | -10…60 |
| Protection | IP 67 |
| Mechanical data |
|---|
| Weight [g] | 325.5 |
| Housing | rectangular |
| Dimensions [mm] | 59 x 42 x 52 |
| Materials | housing: diecast zinc; front lens: glass; LED window: PC |
| Lens alignment | side lens |
| Displays / operating elements |
|---|
| Display | | switching status | 2 x LED, yellow | | operation | LED, green | | distance value, programming | alphanumeric display, 4-digit |
|
| Accessories |
|---|
| Accessories (optional) | |
| Remarks |
|---|
| Remarks | | operating voltage “supply class 2” according to cULus |
|
| Pack quantity | 1 pcs. |
| Electrical connection |
|---|
| Connection | Connector: 1 x M12 |
| Other data |
|---|
| Parameter | Setting range | Factory setting | | Uni | cm, m, inch | cm | | OU1 | Hno, Hnc, Fno, Fnc | Hno | | SP1 [cm] | 20.0…999.5 | 100.0 | | rP1 [cm] | 20.0…999.5 | 80.0 | | OU2 | Hno, Hnc, Fno, Fnc, I, U | I | | SP2 [cm] | 20.0…999.5 | 200.0 | | rP2 [cm] | 20.0…999.5 | 180.0 | | ASP [cm] | 20.0…999.5 | 0 | | AEP [cm] | 20.0…999.5 | 979.5 | | dr1 [s] | 0…0.1…5 | 0 | | dr2 [s] | 0…0.1…5 | 0 | | FOU1 | ON ; OFF | OFF | | FOU2 | ON ; OFF | OFF | | dFO [s] | 0…0.1…5 | 0 | | EMP [cm] | 20.0…999.5 | 20.0 | | cMEd [cm] | 20.0…999.5 | – | | dIS | ON ; OFF | ON | | mEAn [s] | OFF ; 1…60 | OFF | | rATE [Hz] | 1…33 | 15 |
|
| repeatability/accuracy |
|---|
| repeatability of the measured values | | Accuracy | | | white (90 % remission) | grey (18 % remission) | white (90 % remission) | grey (18 % remission) | | 20.0…100.0 cm | ± 0.45 cm | ± 0.6 cm | ± 1.5 cm | ± 1.6 cm | | 100.0…200.0 cm | ± 0.5 cm | ± 0.8 cm | ± 1.5 cm | ± 1.8 cm | | 200.0…400.0 cm | ± 1.6 cm | ± 1.9 cm | ± 2.5 cm | ± 3.0 cm | | 400.0…600.0 cm | ± 2.4 cm | ± 3.3 cm | ± 3.5 cm | ± 4.5 cm | | 600.0…1000.0 cm | ± 5.0 cm | | ± 6.5 cm | |
|
| Sampling rate | 15Hz | | Extraneous light on the object | < 40 klx |
|
| repeatability/accuracy |
|---|
| repeatability of the measured values | | Accuracy | | | white (90 % remission) | grey (18 % remission) | white (90 % remission) | grey (18 % remission) | | 20.0…200.0 cm | ± 1.4 cm | ± 1.4 cm | ± 2.4 cm | ± 2.4 cm | | 200.0…400.0 cm | ± 2.5 cm | ± 3.0 cm | ± 3.5 cm | ± 4.0 cm | | 400.0…600.0 cm | ± 3.1 cm | ± 4.5 cm | ± 4.1 cm | ± 5.5 cm | | 600.0…1000.0 cm | ± 6.0 cm | | ± 7.0 cm | |
|
| Sampling rate | 15Hz | | Extraneous light on the object | 40…100 klx |
|
| repeatability/accuracy |
|---|
| repeatability of the measured values | | Accuracy | | | white (90 % remission) | grey (18 % remission) | white (90 % remission) | grey (18 % remission) | | 20.0…100.0 cm | ± 0.4 cm | ± 0.45 cm | ± 1.4 cm | ± 1.5 cm | | 100.0…200.0 cm | ± 0.45 cm | ± 0.6 cm | ± 1.5 cm | ± 1.6 cm | | 200.0…400.0 cm | ± 1.35 cm | ± 1.4 cm | ± 2.3 cm | ± 2.4 cm | | 400.0…600.0 cm | ± 1.9 cm | ± 2.1 cm | ± 2.9 cm | ± 3.1 cm | | 600.0…1000.0 cm | ± 3.7 cm | | ± 4.7 cm | |
|
| Sampling rate | 1 Hz | | Extraneous light on the object | < 40 klx |
|
| repeatability/accuracy |
|---|
| repeatability of the measured values | | Accuracy | | | white (90 % remission) | grey (18 % remission) | white (90 % remission) | grey (18 % remission) | | 20.0…200.0 cm | ± 1.0 cm | ± 1.0 cm | ± 2.0 cm | ± 2.0 cm | | 200.0…400.0 cm | ± 1.8 cm | ± 1.9 cm | ± 2.8 cm | ± 2.9 cm | | 400.0…600.0 cm | ± 2.3 cm | ± 2.7 cm | ± 3.3 cm | ± 3.7 cm | | 600.0…1000.0 cm | ± 3.8 cm | | ± 4.8 cm | |
|
| Sampling rate | 1 Hz | | Extraneous light on the object | 40…100 klx | | Range on black object (6 % remission) | <= 4000 mm | | The values apply at | | | constant ambient conditions | 23 °C / 960 hPa | | minimum power-on time in minutes | 10 |
|