Product characteristics |
---|
Type of light | red light |
Image resolution [px] | 640 x 480 |
Lens type | Telephoto lens |
Max. reading rate [Hz] | 20 |
Communication interface | Ethernet; RS232 |
Dimensions [mm] | 60 x 42 x 59 |
Electrical data |
---|
Operating voltage tolerance [%] | 10 |
Operating voltage [V] | 24 DC |
Current consumption [mA] | < 300 |
Protection class | III |
Reverse polarity protection | yes |
Type of light | red light |
Wave length [nm] | 625 |
Image sensor | CMOS image sensor black/white |
Internal lighting | yes; (red light: 625 nm 4 lighting segments individual control via PC operating program) |
Laser marking | yes; (red; Laser protection class 2 DIN EN 60825-1) |
Inputs / outputs |
---|
Number of inputs and outputs | Number of digital outputs: 2 |
Inputs |
---|
Trigger | internal; 24 V PNP (IEC 61131-2 Typ 1); RS-232; TCP/IP; EtherNet/IP |
Outputs |
---|
Total number of outputs | 2 |
Number of digital outputs | 2; (configurable) |
Output function | 24 V PNP |
Max. voltage drop switching output DC [V] | 2 |
Max. current load per output [mA] | 100 |
Short-circuit protection | yes |
Overload protection | yes |
Detection zone |
---|
Field of view size [mm] | Operating distance | field of view | Smallest detectable object | Resolution | 75 | 15 x 11 | | | 100 | 20 x 15 | | | 200 | 40 x 30 | | | 400 | 80 x 60 | | | 1000 | 200 x 150 | | | 2000 | 400 x 300 | | |
|
Operating distance [mm] | > 75 |
Image resolution [px] | 640 x 480 |
Lens type | Telephoto lens |
Readable codes | Interleaved 2-of-5; Industrial 2-of-5; Code 39; Code 93; Code 128; Pharmacode; Codabar; EAN8; EAN8 Add-On 2; EAN8 Add-On 5; EAN13; EAN13 Add-On 2; EAN13 Add-On 5; UPC-A; UPC-A Add-On 2; UPC-A Add-On 5; UPC-E; UPC-E Add-On 2; UPC-E Add-On 5; GS1 DataBar Omnidirectional; GS1 DataBar Truncated; GS1 DataBar Stacked; GS1 DataBar Stacked Omnidirectional; GS1 DataBar Limited; GS1 DataBar Expanded; GS1 DataBar Expanded Stacked; GS1 – 128; MSI Barcode; ECC200; PDF-417; QR; Micro-QR; Aztec Code; GS1 ECC200; GS1 QR Code; GS1 Aztec Code |
Legible fonts | Industrial; Document |
Text recognition | yes |
Omnidirectional reading | yes |
Max. inclination to the image plane [°] | 45 |
Max. reading rate [Hz] | 20 |
Software / programming |
---|
Parameter setting options | via two pushbuttons and 10-segment display or via PC / notebook with operating software |
Interfaces |
---|
Communication interface | Ethernet; RS232 |
Number of R232 interfaces | 1 |
Ethernet |
---|
Number of Ethernet interfaces | 1 |
Transmission standard | 10Base-T; 100Base-TX |
Transmission rate | 10; 100 |
Protocol | TCP/IP; UDP; EtherNet/IP |
Factory settings | IP address: 192.168.0.79 | subnet mask: 255.255.255.0 | gateway IP address: 192.168.0.201 | MAC address: see type label |
|
Operating conditions |
---|
Ambient temperature [°C] | -10…50 |
Storage temperature [°C] | -40…85 |
Protection | IP 67 |
Mechanical data |
---|
Weight [K40] | 449.5 |
Dimensions [mm] | 60 x 42 x 59 |
Materials | housing: diecast zinc powder-coated; front lens: glass; LED window: PC |
Displays / operating elements |
---|
Display | function | 3 x LED, green | switching status | 4 x LED, yellow | | 10-segment display, 4-digit |
|
Accessories |
---|
Accessories (optional) | Operating software | Mounting accessories |
|
Remarks |
---|
Remarks | operating voltage “supply class 2” according to cULus |
|
Notes | For 8-pole sockets the core colours are not standardised.; Please note the wiring of the sensor and the sockets (see data sheet). |
Pack quantity | 1 pcs. |
Electrical connection – Ethernet |
---|
| Connector: 1 x M12 |
Electrical connection – RS-232 |
---|
| Connector: 1 x M12 |