| Product characteristics |
|---|
| Type of light | red light |
| Communication interface | IO-Link |
| Laser protection class | 1 |
| Housing | rectangular |
| Dimensions [mm] | 46 x 13 x 21 |
| Application |
|---|
| Special feature | Background suppression |
| Function principle | Diffuse reflection sensor |
| Electrical data |
|---|
| Operating voltage [V] | 10…30 DC |
| Current consumption [mA] | 16; (24 V) |
| Protection class | III |
| Reverse polarity protection | yes |
| Type of light | red light |
| Wave length [nm] | 650 |
| Outputs |
|---|
| Electrical design | NPN |
| Output function | light-on/dark-on mode; (selectable) |
| Max. voltage drop switching output DC [V] | 2.5 |
| Permanent current rating of switching output DC [mA] | 100 |
| Switching frequency DC [Hz] | 1000 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Detection zone |
|---|
| Range [mm] | 1…100; (white paper 200 x 200 mm) |
| Range on white object (90 % remission) [mm] | 1…100 |
| Range on grey object (18 % remission) [mm] | 8…100 |
| Range on black object (6 % remission) [mm] | 12…100 |
| Range adjustable | yes |
| Max. light spot diameter [mm] | 2 |
| Light spot dimensions refer to | at maximum range |
| Background suppression available | yes |
| Interfaces |
|---|
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor: Device Identification; Device Diagnosis; Teach Channel; Switching Channel; Process Data Variable |
| SIO mode | yes |
| Required master port type | A |
| Min. process cycle time [ms] | 10 |
| IO-Link process data (cyclical) | | function | bit length | | process value | 32 | | device status | 4 | | binary switching information | 1 |
|
| IO-Link functions (acyclical) | application specific tag; operating hours counter; switch-on cycle counter |
| Supported DeviceIDs | | Type of operation | DeviceID | | Default | 526 |
|
| Operating conditions |
|---|
| Ambient temperature [°C] | -10…60 |
| Protection | IP 65; IP 67 |
| Mechanical data |
|---|
| Weight [g] | 19.1 |
| Housing | rectangular |
| Dimensions [mm] | 46 x 13 x 21 |
| Materials | housing: ABS; PPSU; Sealing: EPDM |
| Lens material | |
| Lens alignment | side lens |
| Displays / operating elements |
|---|
| Display | | switching status | 1 x LED, yellow | | operation | 1 x LED, green |
|
| Remarks |
|---|
| Remarks | | operating voltage “supply class 2” according to cULus |
|
| Pack quantity | 1 pcs. |
| Electrical connection |
|---|
| Connection | Connector: 1 x M8 |
| Other data |
|---|
| Repeatability: 6 σ |
|---|
| repeatability of the measured values | | | Abstand | white (90 % remission) | black (6 %…90 % remission) | | 20 mm | 0.1 mm | 0.5 mm | | 50 mm | 0.2 mm | 1.0 mm | | 100 mm | 0.5 mm | 2.0 mm | | | | | Accuracy | | | Abstand | white (90 % remission) | black (6 %…90 % remission) | | 20 mm | ± 0.6 mm | ± 0.9 mm | | 50 mm | ± 1.5 mm | ± 2.0 mm | | 100 mm | ± 3.0 mm | ± 4.0 mm | | | |
|
| The values apply at | | | Extraneous light on the object | < 10 klx | | constant ambient conditions | 23 °C / 960 hPa | | minimum power-on time in minutes | 10 | | IO-Link – measuring mode | |
|