| Product characteristics |
|---|
| Type of light | red light |
| Communication interface | IO-Link |
| Laser protection class | 1 |
| Dimensions [mm] | 61.7 x 22.5 x 45.2 |
| Application |
|---|
| Application [m] | 0.03…1.5 |
| Electrical data |
|---|
| Operating voltage [V] | 10…30 DC; (“supply class 2” to cULus) |
| Current consumption [mA] | < 75 |
| Current consumption reference voltage [V] | 24 |
| Protection class | III |
| Reverse polarity protection | yes |
| Type of light | red light |
| Wave length [nm] | 650 |
| Typ. lifetime [h] | 50000 |
| Outputs |
|---|
| Electrical design | PNP |
| Output function | 2 x normally open, 2 x normally closed; (parameterisable) |
| Permanent current rating of switching output DC [mA] | 100; (per output) |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
| Detection zone |
|---|
| Max. light spot width [mm] | 5 |
| Max. light spot height [mm] | 5 |
| Light spot dimensions refer to | at maximum range |
| Background suppression [m] | 0.03…20 |
| Measuring/setting range |
|---|
| Measuring range [m] | 0.025…1.5 |
| Sampling rate [Hz] | 33 |
| Interfaces |
|---|
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 2 |
| Process data binary | 2 |
| Min. process cycle time [ms] | 6 |
| Supported DeviceIDs | | Type of operation | DeviceID | | Default | 925 |
|
| Operating conditions |
|---|
| Ambient temperature [°C] | -25…60 |
| Note on ambient temperature | | In ambient temperatures < -10 °C a warm-up time is necessary. | | Laser is off. |
|
| Storage temperature [°C] | -30…80 |
| Protection | IP 65; IP 67 |
| Mechanical data |
|---|
| Weight [g] | 221.3 |
| Dimensions [mm] | 61.7 x 22.5 x 45.2 |
| Materials | Housing: stainless steel (1.4404 / 316L); PPSU; ABS; PMMA; PBT / PC; EPDM; front lens: glass |
| Displays / operating elements |
|---|
| Display | | switching status | 2 x LED, yellow | | 1 x alphanumeric display, 3-digit |
|
| Accessories |
|---|
| Accessories (supplied) | |
| Remarks |
|---|
| Pack quantity | 1 pcs. |
| Electrical connection |
|---|
| Connection | Connector: 1 x M12 |
| Other data |
|---|
| Parameter | Setting range | Factory setting | | Uni | cm, inch | cm | | OU1 | Hno, Hnc, Fno, Fnc, OFF | Hno | | SP1 [cm] | 3…150 | 150 | | nP1 [cm] | 3…150 | 20 | | FSP1 [cm] | 3…150 | 25 | | OU2 | Hno, Hnc, Fno, Fnc, OFF | Hno | | SP2 [cm] | 3…150 | 3 | | nP2 [cm] | 3…150 | 30 | | FP2 [cm] | 3…150 | 35 | | dS1 [s] | 0…0.1…5 | 0 | | dr1 [s] | 0…0.1…5 | 0 | | dS2 [s] | 0…0.1…5 | 0 | | dr2 [s] | 0…0.1…5 | 0 | | dFo [s] | 0…0.1…5 | 0.1 | | dIS | ON / OFF | ON |
|
| Repeatability: 6 σ |
|---|
| repeatability of the measured values | | | distance | white (90 % remission) | black (6 %…90 % remission) | | 25 mm | 8.0 mm | 15.0 mm | | 750 mm | 8.0 mm | 15.0 mm | | 1500 mm | 20.0 mm | 60.0 mm |
|
| The values apply at | | | Extraneous light on the object | < 10 klx | | constant ambient conditions | 23 °C / 960 hPa | | minimum power-on time in minutes | 10 |
|