Product characteristics |
---|
Type of light | red light |
Communication interface | IO-Link |
Laser protection class | 1 |
Dimensions [mm] | 61.7 x 22.5 x 45.2 |
Application |
---|
Application [m] | 0.03…1.5 |
Electrical data |
---|
Operating voltage [V] | 10…30 DC; (“supply class 2” to cULus) |
Current consumption [mA] | < 75 |
Current consumption reference voltage [V] | 24 |
Protection class | III |
Reverse polarity protection | yes |
Type of light | red light |
Wave length [nm] | 650 |
Typ. lifetime [h] | 50000 |
Outputs |
---|
Electrical design | PNP |
Output function | 2 x normally open / normally closed; (parameterisable) |
Permanent current rating of switching output DC [mA] | 100; (per output) |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Detection zone |
---|
Range [mm] | 1500 |
Max. light spot width [mm] | 5 |
Max. light spot height [mm] | 5 |
Light spot dimensions refer to | at maximum range |
Background suppression [m] | 0.03…20 |
Measuring/setting range |
---|
Measuring range [m] | 0.025…1.5 |
Sampling rate [Hz] | 33 |
Interfaces |
---|
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
SDCI standard | IEC 61131-9 |
Profiles | Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis |
SIO mode | yes |
Required master port type | A |
Process data analogue | 2 |
Process data binary | 2 |
Min. process cycle time [ms] | 6 |
Supported DeviceIDs | Type of operation | DeviceID | Default | 1065 |
|
Operating conditions |
---|
Ambient temperature [°C] | -25…60 |
Note on ambient temperature | In ambient temperatures < -10 °C a warm-up time is necessary. | Laser is off. |
|
Storage temperature [°C] | -30…80 |
Protection | IP 65; IP 67 |
Mechanical data |
---|
Weight [g] | 205.5 |
Dimensions [mm] | 61.7 x 22.5 x 45.2 |
Materials | Housing: stainless steel (1.4404 / 316L); PPSU; ABS; PMMA; PBT / PC; EPDM; front lens: glass |
Displays / operating elements |
---|
Display | switching status | 2 x LED, yellow | | 1 x alphanumeric display, 3-digit |
|
Accessories |
---|
Accessories (supplied) | |
Remarks |
---|
Pack quantity | 1 pcs. |
Electrical connection |
---|
Connection | Connector: 1 x M12 |
Other data |
---|
Parameter | Setting range | Factory setting | OU1 | Hno, Hnc, Fno, Fnc, OFF | Hno | SP1 [cm] | 3…150 | 150 | nP1 [cm] | 3…150 | 20 | FSP1 [cm] | 3…150 | 25 | OU2 | Hno, Hnc, Fno, Fnc, OFF | Hno | SP2 [cm] | 3…150 | 3 | nP2 [cm] | 3…150 | 30 | FP2 [cm] | 3…150 | 35 | dS1 [s] | 0…0.1…5 | 0 | dr1 [s] | 0…0.1…5 | 0 | dS2 [s] | 0…0.1…5 | 0 | dr2 [s] | 0…0.1…5 | 0 | dFo [s] | 0…0.1…5 | 0.1 | dIS | ON / OFF | ON |
|
Repeatability: 6 σ |
---|
| repeatability of the measured values | | distance | white (90 % remission) | black (6 % remission) | 25 mm | 8.0 mm | 15.0 mm | 750 mm | 8.0 mm | 15.0 mm | 1500 mm | 20.0 mm | 60.0 mm |
|
The values apply at | | Extraneous light on the object | < 10 klx | constant ambient conditions | 23 °C / 960 hPa | minimum power-on time in minutes | 10 |
|