|  Product characteristics | 
|---|
|  Output signal |  switching signal; analogue signal; IO-Link; (configurable) | 
|  Measuring range | |  -1…10 bar |  -14.5…145 psi |  -0.1…1 MPa |  
  | 
|  Process connection |  threaded connection G 1 external thread sealing cone | 
|  Application | 
|---|
|  Special feature |  Gold-plated contacts | 
|  Application |  food and beverage industry | 
|  Media |  viscous media and liquids with suspended particles; liquids and gases | 
|  Medium temperature [°C] |  -25…125; (145 max. 1h) | 
|  Min. bursting pressure |  | 
|  Pressure rating |  | 
|  Vacuum resistance [mbar] |  -1000 | 
|  Type of pressure |  relative pressure; vacuum | 
|  MAWP (for applications according to CRN) [bar] |  50 | 
|  Electrical data | 
|---|
|  Min. insulation resistance [MΩ] |  100; (500 V DC) | 
|  Protection class |  III | 
|  Reverse polarity protection |  yes | 
|  Integrated watchdog |  yes | 
|  2-wire | 
|---|
|  Operating voltage [V] |  20…32 DC | 
|  Current consumption [mA] |  3.6…21 | 
|  Power-on delay time [s] |  1 | 
|  3-wire | 
|---|
|  Operating voltage [V] |  18…32 DC | 
|  Current consumption [mA] |  < 45 | 
|  Power-on delay time [s] |  0.5 | 
|  Inputs / outputs | 
|---|
|  Number of inputs and outputs |  Number of digital outputs: 2; Number of analogue outputs: 1 | 
|  Outputs | 
|---|
|  Total number of outputs |  2 | 
|  Output signal |  switching signal; analogue signal; IO-Link; (configurable) | 
|  Electrical design |  PNP/NPN | 
|  Number of digital outputs |  2 | 
|  Output function |  normally open / normally closed; (parameterisable) | 
|  Number of analogue outputs |  1 | 
|  Analogue current output [mA] |  4…20, invertible; (scalable) | 
|  Short-circuit protection |  yes | 
|  Type of short-circuit protection |  pulsed | 
|  Overload protection |  yes | 
|  2-wire | 
|---|
|  Max. load [Ω] |  300 | 
|  3-wire | 
|---|
|  Max. voltage drop switching output DC [V] |  2 | 
|  Permanent current rating of switching output DC [mA] |  250 | 
|  Switching frequency DC [Hz] |  125 | 
|  Max. load [Ω] |  (Ub – 10 V) / 20 mA | 
|  Measuring/setting range | 
|---|
|  Measuring range | |  -1…10 bar |  -14.5…145 psi |  -0.1…1 MPa |  
  | 
|  Set point SP | |  -0.98…10 bar |  -14.2…145 psi |  -0.098…1 MPa |  
  | 
|  Reset point rP | |  -1…9.98 bar |  -14.5…144.7 psi |  -0.1…0.998 MPa |  
  | 
|  Analogue start point | |  -1…7.5 bar |  -14.5…108.7 psi |  -0.1…0.75 MPa |  
  | 
|  Analogue end point | |  1.5…10 bar |  21.8…145 psi |  0.15…1 MPa |  
  | 
|  In steps of | |  0.01 bar |  0.1 psi |  0.001 MPa |  
  | 
|  Factory setting |  |  SP1 = 2.50 bar |  rP1 = 2.30 bar |   |  SP2 = 7.50 bar |  rP2 = 7.30 bar |   |  ASP = 0.00 bar |  AEP = 10.00 bar |  
  | 
|  Accuracy / deviations | 
|---|
|  Switch point accuracy [% of the span] |  < ± 0,2; (Turn down 1:1) | 
|  Repeatability [% of the span] |  < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) | 
|  Characteristics deviation [% of the span] |  < ± 0,2; (Turn down 1:1 linearity, incl. hysteresis and repeatability limit value setting to DIN 16086) | 
|  Linearity deviation [% of the span] |  < ± 0,15; (Turn down 1:1) | 
|  Hysteresis deviation [% of the span] |  < ± 0,15; (Turn down 1:1) | 
|  Long-term stability [% of the span] |  < ± 0,1; (Turn down 1:1; per year) | 
|  Temperature coefficient zero point [% of the span / 10 K] |  < ± 0,05; (0…70 °C) | 
|  Temperature coefficient span [% of the span / 10 K] |  < ± 0,15; (0…70 °C) | 
|  Response times | 
|---|
|  Damping for the switching output dAP [s] |  0…30 | 
|  Damping for the analogue output dAA [s] |  0.01…99.99 | 
|  2-wire | 
|---|
|  Step response time analogue output [ms] |  45 | 
|  3-wire | 
|---|
|  Min. response time of switching output (dAP) [ms] |  3 | 
|  Step response time analogue output [ms] |  7 | 
|  Interfaces | 
|---|
|  Communication interface |  IO-Link | 
|  Transmission type |  COM2 (38,4 kBaud) | 
|  IO-Link revision |  1.0 | 
|  Profiles |  no profile | 
|  SIO mode |  yes | 
|  Required master port type |  A | 
|  Process data analogue |  1 | 
|  Process data binary |  2 | 
|  Min. process cycle time [ms] |  2.3 | 
|  Supported DeviceIDs | |  Type of operation |  DeviceID |  |  Default |  157 |  
  | 
|  Operating conditions | 
|---|
|  Ambient temperature [°C] |  -25…80 | 
|  Storage temperature [°C] |  -40…100 | 
|  Protection |  IP 67; IP 68; IP 69K | 
|  Mechanical data | 
|---|
|  Weight [g] |  378.8 | 
|  Materials |  stainless steel (1.4404 / 316L); FKM; PTFE; PBT; PEI; PFA | 
|  Materials (wetted parts) |  ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE | 
|  Min. pressure cycles |  100 million | 
|  Process connection |  threaded connection G 1 external thread sealing cone | 
|  Displays / operating elements | 
|---|
|  Display | |  Display unit |  LED, green |  |  switching status |  LED, yellow |  |  function display |  alphanumeric display, 4-digit |  |  measured values |  alphanumeric display, 4-digit |  
  | 
|  Display unit |  bar; psi; MPa; % of the span | 
|  Remarks | 
|---|
|  Remarks | |  Attention: The unit must only be installed in a process connection for G1 sealing cone. |  |  The G1A sealing cone of the unit is only suited for adapters with metal end stop. |  
  | 
|  Pack quantity |  1 pcs. | 
|  Electrical connection | 
|---|
|  Connection |  Connector: 1 x M12; Contacts: gold-plated |