Product characteristics |
---|
Output signal | switching signal; analogue signal; IO-Link; (configurable) |
Measuring range | -1…1 bar | -1000…1000 mbar | -14.5…14.5 psi | -100…100 kPa |
|
Process connection | threaded connection G 1 external thread sealing cone |
Application |
---|
Special feature | Gold-plated contacts |
Application | food and beverage industry |
Media | viscous media and liquids with suspended particles; liquids and gases |
Medium temperature [°C] | -25…125; (145 max. 1h) |
Min. bursting pressure | 30000 mbar | 435 psi | 3000 kPa |
|
Pressure rating | 10000 mbar | 145 psi | 1000 kPa |
|
Vacuum resistance [mbar] | -1000 |
Type of pressure | relative pressure; vacuum |
MAWP (for applications according to CRN) [bar] | 10 |
Electrical data |
---|
Min. insulation resistance [MΩ] | 100; (500 V DC) |
Protection class | III |
Reverse polarity protection | yes |
Integrated watchdog | yes |
2-wire |
---|
Operating voltage [V] | 20…32 DC |
Current consumption [mA] | 3.6…21 |
Power-on delay time [s] | 1 |
3-wire |
---|
Operating voltage [V] | 18…32 DC |
Current consumption [mA] | < 45 |
Power-on delay time [s] | 0.5 |
Inputs / outputs |
---|
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Outputs |
---|
Total number of outputs | 2 |
Output signal | switching signal; analogue signal; IO-Link; (configurable) |
Electrical design | PNP/NPN |
Number of digital outputs | 2 |
Output function | normally open / normally closed; (parameterisable) |
Number of analogue outputs | 1 |
Analogue current output [mA] | 4…20, invertible; (scalable) |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
2-wire |
---|
Max. load [Ω] | 300 |
3-wire |
---|
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 250 |
Switching frequency DC [Hz] | 125 |
Max. load [Ω] | (Ub – 10 V) / 20 mA |
Measuring/setting range |
---|
Measuring range | -1…1 bar | -1000…1000 mbar | -14.5…14.5 psi | -100…100 kPa |
|
Set point SP | -998…1000 mbar | -14.45…14.5 psi | -99.8…100 kPa |
|
Reset point rP | -1000…998 mbar | -14.5…14.45 psi | -100…99.8 kPa |
|
Analogue start point | -1000…500 mbar | -14.5…7.25 psi | -100…50 kPa |
|
Analogue end point | -500…1000 mbar | -7.25…14.5 psi | -50…100 kPa |
|
In steps of | |
Factory setting | | SP1 = -500 mbar | rP1 = -540 mbar | | SP2 = 500 mbar | rP2 = 460 mbar | | ASP = -1000 mbar | AEP = 1000 mbar |
|
Accuracy / deviations |
---|
Switch point accuracy [% of the span] | < ± 0,2; (Turn down 1:1) |
Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
Characteristics deviation [% of the span] | < ± 0,2; (Turn down 1:1 linearity, incl. hysteresis and repeatability limit value setting to DIN 16086) |
Linearity deviation [% of the span] | < ± 0,15; (Turn down 1:1) |
Hysteresis deviation [% of the span] | < ± 0,15; (Turn down 1:1) |
Long-term stability [% of the span] | < ± 0,1; (Turn down 1:1; per year) |
Temperature coefficient zero point [% of the span / 10 K] | < ± 0,05; (0…70 °C) |
Temperature coefficient span [% of the span / 10 K] | < ± 0,15; (0…70 °C) |
Response times |
---|
Damping for the switching output dAP [s] | 0…30 |
Damping for the analogue output dAA [s] | 0.01…99.99 |
2-wire |
---|
Step response time analogue output [ms] | 45 |
3-wire |
---|
Min. response time of switching output (dAP) [ms] | 3 |
Step response time analogue output [ms] | 7 |
Interfaces |
---|
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.0 |
Profiles | no profile |
SIO mode | yes |
Required master port type | A |
Process data analogue | 1 |
Process data binary | 2 |
Min. process cycle time [ms] | 2.3 |
Supported DeviceIDs | Type of operation | DeviceID | Default | 258 |
|
Operating conditions |
---|
Ambient temperature [°C] | -25…80 |
Storage temperature [°C] | -40…100 |
Protection | IP 67; IP 68; IP 69K |
Mechanical data |
---|
Weight [g] | 379 |
Materials | stainless steel (1.4404 / 316L); FKM; PTFE; PBT; PEI; PFA |
Materials (wetted parts) | ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE |
Min. pressure cycles | 100 million |
Process connection | threaded connection G 1 external thread sealing cone |
Displays / operating elements |
---|
Display | Display unit | LED, green | switching status | LED, yellow | function display | alphanumeric display, 4-digit | measured values | alphanumeric display, 4-digit |
|
Display unit | mbar; kPa; psi; inH2O; mWS; % of the span |
Remarks |
---|
Remarks | Attention: The unit must only be installed in a process connection for G1 sealing cone. | The G1A sealing cone of the unit is only suited for adapters with metal end stop. |
|
Pack quantity | 1 pcs. |
Electrical connection |
---|
Connection | Connector: 1 x M12; Contacts: gold-plated |