|  Product characteristics | 
|---|
|  Output signal |  analogue signal; (configurable) | 
|  Measuring range | |  -1…1 bar |  -1000…1000 mbar |  -14.5…14.5 psi |  -100…100 kPa |  
  | 
|  Process connection |  threaded connection G 1 external thread Aseptoflex Vario | 
|  Application | 
|---|
|  Special feature |  Gold-plated contacts | 
|  Measuring element |  ceramic-capacitive pressure measuring cell | 
|  Application |  food and beverage industry | 
|  Media |  viscous media and liquids with suspended particles; liquids and gases | 
|  Medium temperature [°C] |  -25…125; (150 max. 1h) | 
|  Min. bursting pressure | |  30000 mbar |  435 psi |  3000 kPa |  
  | 
|  Pressure rating | |  10000 mbar |  145 psi |  1000 kPa |  
  | 
|  Vacuum resistance [mbar] |  -1000 | 
|  Type of pressure |  relative pressure; vacuum | 
|  No dead space |  yes | 
|  MAWP (for applications according to CRN) [bar] |  10 | 
|  Electrical data | 
|---|
|  Operating voltage [V] |  18…30 DC | 
|  Min. insulation resistance [MΩ] |  100; (500 V DC) | 
|  Protection class |  III | 
|  Reverse polarity protection |  yes | 
|  Integrated watchdog |  yes | 
|  2-wire | 
|---|
|  Current consumption [mA] |  3.5…21.5 | 
|  Power-on delay time [s] |  1 | 
|  3-wire | 
|---|
|  Current consumption [mA] |  < 45 | 
|  Power-on delay time [s] |  0.5 | 
|  Inputs / outputs | 
|---|
|  Number of inputs and outputs |  Number of analogue outputs: 1 | 
|  Outputs | 
|---|
|  Total number of outputs |  1 | 
|  Output signal |  analogue signal; (configurable) | 
|  Number of analogue outputs |  1 | 
|  Analogue current output [mA] |  4…20; (scalable) | 
|  Max. load [Ω] |  700; (Ub = 24 V; (Ub – 9 V) / 21.5 mA) | 
|  Short-circuit proof |  yes | 
|  Overload protection |  yes | 
|  Measuring/setting range | 
|---|
|  Measuring range | |  -1…1 bar |  -1000…1000 mbar |  -14.5…14.5 psi |  -100…100 kPa |  
  | 
|  Analogue start point | |  -1000…600 mbar |  -14.5…8.7 psi |  -100…60 kPa |  
  | 
|  Analogue end point | |  -600…1000 mbar |  -8.7…14.5 psi |  -60…100 kPa |  
  | 
|  In steps of |  | 
|  Factory setting |  |  ASP = -1000 mbar |  AEP = 1000 mbar |  
  | 
|  Accuracy / deviations | 
|---|
|  Repeatability [% of the span] |  < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) | 
|  Characteristics deviation [% of the span] |  < ± 0,2 (DIN EN 61298-2); (incl. zero point and span error, non-linearity, hysteresis ; Turn down 1:1) | 
|  Linearity deviation [% of the span] |  < ± 0,15; (Turn down 1:1) | 
|  Hysteresis deviation [% of the span] |  < ± 0,15; (Turn down 1:1) | 
|  Long-term stability [% of the span] |  < ± 0,1; (Turn down 1:1; per year) | 
|  Temperature coefficient zero point [% of the span / 10 K] |  < ± 0,05; (0…70 °C) | 
|  Temperature coefficient span [% of the span / 10 K] |  < ± 0,15; (0…70 °C) | 
|  Response times | 
|---|
|  Damping for the analogue output dAA [s] |  0…4 | 
|  2-wire | 
|---|
|  Step response time analogue output [ms] |  30 | 
|  3-wire | 
|---|
|  Step response time analogue output [ms] |  7 | 
|  Interfaces | 
|---|
|  Communication interface |  IO-Link | 
|  Transmission type |  COM2 (38,4 kBaud) | 
|  IO-Link revision |  1.1 | 
|  Profiles |  Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) | 
|  SIO mode |  no | 
|  Required master port type |  A | 
|  Process data analogue |  3 | 
|  Min. process cycle time [ms] |  3.2 | 
|  Supported DeviceIDs | |  Type of operation |  DeviceID |  |  Default |  667 |  
  | 
|  Operating conditions | 
|---|
|  Ambient temperature [°C] |  -25…80 | 
|  Storage temperature [°C] |  -40…100 | 
|  Protection |  IP 67; IP 68; IP 69K | 
|  Mechanical data | 
|---|
|  Weight [g] |  281 | 
|  Materials |  stainless steel (1.4404 / 316L); PBT | 
|  Materials (wetted parts) |  ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE | 
|  Min. pressure cycles |  100 million | 
|  Tightening torque [Nm] |  35 | 
|  Process connection |  threaded connection G 1 external thread Aseptoflex Vario | 
|  Displays / operating elements | 
|---|
|  Display unit |  mbar; psi; kPa; mWS; inH2O | 
|  Remarks | 
|---|
|  Pack quantity |  1 pcs. | 
|  Electrical connection | 
|---|
|  Connection |  Connector: 1 x M12; Contacts: gold-plated |