| Product characteristics |
|---|
| Output signal | switching signal; IO-Link; (configurable) |
| Measuring range | | 0…2.5 bar | 0…2500 mbar | 0…36.3 psi | 0…250 kPa |
|
| Process connection | threaded connection G 1/4 internal thread |
| Application |
|---|
| Special feature | Gold-plated contacts |
| Application | for industrial applications |
| Media | liquids and gases |
| Medium temperature [°C] | -20…60 |
| Min. bursting pressure | |
| Pressure rating | |
| Type of pressure | relative pressure |
| Electrical data |
|---|
| Operating voltage [V] | 18…36 DC; (according to EN 50178 SELV/PELV) |
| Current consumption [mA] | < 50 |
| Protection class | III |
| Reverse polarity protection | yes |
| Overvoltage protection | yes; (< 40 V) |
| Power-on delay time [s] | 0.3 |
| Integrated watchdog | yes |
| Inputs / outputs |
|---|
| Number of inputs and outputs | Number of digital outputs: 2 |
| Outputs |
|---|
| Total number of outputs | 2 |
| Output signal | switching signal; IO-Link; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] | 2 |
| Permanent current rating of switching output DC [mA] | 250 |
| Switching frequency DC [Hz] | < 170 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Measuring/setting range |
|---|
| Measuring range | | 0…2.5 bar | 0…2500 mbar | 0…36.3 psi | 0…250 kPa |
|
| Set point SP | | 0.02…2.5 bar | 0.4…36.2 psi | 2…250 kPa |
|
| Reset point rP | | 0.01…2.49 bar | 0.2…36 psi | 1…249 kPa |
|
| In steps of | |
| Factory setting | | SP1 = 0.63 bar | rP1 = 0.58 bar | | | SP2 = 1.88 bar | rP2 = 1.83 bar | |
|
| Accuracy / deviations |
|---|
| Switch point accuracy [% of the span] | < ± 0,5 |
| Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) |
| Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
| Hysteresis deviation [% of the span] | < ± 0,25 |
| Long-term stability [% of the span] | < ± 0,05; (per 6 months) |
| Temperature coefficient zero point [% of the span / 10 K] | 0,2; (0…60 °C) |
| Temperature coefficient span [% of the span / 10 K] | 0,2; (0…60 °C) |
| Response times |
|---|
| Delay time programmable dS, dr [s] | 0; 0,2…50 |
| Software / programming |
|---|
| Parameter setting options | hysteresis / window; normally open / normally closed; diagnostic function; switching logic; switch-on/switch-off delay; Damping; Display unit |
| Interfaces |
|---|
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 CDV |
| Profiles | no profile |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 1 |
| Process data binary | 2 |
| Min. process cycle time [ms] | 2.3 |
| Supported DeviceIDs | | Type of operation | DeviceID | | Default | 312 |
|
| Operating conditions |
|---|
| Ambient temperature [°C] | -20…60 |
| Storage temperature [°C] | -40…100 |
| Protection | IP 65 |
| Mechanical data |
|---|
| Weight [g] | 303 |
| Materials | stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); PC; PBT; PEI; FKM; PTFE |
| Materials (wetted parts) | stainless steel (1.4305 / 303); ceramics; FKM |
| Min. pressure cycles | 100 million |
| Process connection | threaded connection G 1/4 internal thread |
| Restrictor element integrated | no (can be retrofitted) |
| Displays / operating elements |
|---|
| Display | | Display unit | 3 x LED, green | | switching status | 2 x LED, yellow | | function display | alphanumeric display, 4-digit | | measured values | alphanumeric display, 4-digit |
|
| Remarks |
|---|
| Pack quantity | 1 pcs. |
| Electrical connection |
|---|
| Connector: 1 x M12; Contacts: gold-plated |