| Product characteristics |
|---|
| Output signal | switching signal |
| Measuring range [bar] | 0…10 |
| Process connection | threaded connection G 1/4 internal thread |
| Application |
|---|
| Special feature | Gold-plated contacts |
| Application | for industrial applications |
| Media | liquids and gases |
| Medium temperature [°C] | -25…80 |
| Min. bursting pressure [bar] | 150 |
| Pressure rating [bar] | 50 |
| Type of pressure | relative pressure |
| Electrical data |
|---|
| Operating voltage [V] | 18…30 DC |
| Current consumption [mA] | < 90 |
| Min. insulation resistance [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | 0.2 |
| Integrated watchdog | yes |
| Inputs / outputs |
|---|
| Number of inputs and outputs | Number of digital outputs: 2 |
| Inputs |
|---|
| Analogue input (current) [mA] | 0…20 |
| Max. load [Ω] | 300 |
| Analogue input (voltage) [V] | 0…10 |
| Min. load resistance [Ω] | 90000 |
| Outputs |
|---|
| Total number of outputs | 2 |
| Output signal | switching signal |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] | 2 |
| Permanent current rating of switching output DC [mA] | 250 |
| Switching frequency DC [Hz] | < 170 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
| Measuring/setting range |
|---|
| Measuring range [bar] | 0…10 |
| Set point SP [bar] | -2.46…10 |
| Note on setpoint SP | |
| Reset point rP [bar] | -2.5…9.96 |
| Note on setpoint SP | |
| In steps of [bar] | 0.02 |
| Accuracy / deviations |
|---|
| Characteristics deviation [% of the final value] | < ± 0,6 |
| Temperature drift per 10 K | < ± 0.3 |
| Characteristics deviation analogue input | < ± 0.3 |
| Temperature drift analogue input per 10 K | < ± 0.1 |
| Temperature drift analogue input [°C] | 0…80 |
| Response times |
|---|
| Response time [ms] | < 3 |
| Delay time programmable dS, dr [s] | 0, 0,1…50 |
| Damping for the switching output dAP [s] | 0…4 |
| Software / programming |
|---|
| Adjustment of the switch point | programming button |
| Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; current/voltage input; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit |
| Operating conditions |
|---|
| Ambient temperature [°C] | -25…80 |
| Storage temperature [°C] | -40…100 |
| Protection | IP 65 |
| Mechanical data |
|---|
| Weight [g] | 289 |
| Materials | stainless steel (1.4305 / 303); PBT; PC; PA; FKM |
| Materials (wetted parts) | stainless steel (1.4305 / 303); ceramics; FKM |
| Min. pressure cycles | 100 million |
| Process connection | threaded connection G 1/4 internal thread |
| Restrictor element integrated | no (can be retrofitted) |
| Displays / operating elements |
|---|
| Display | | Display unit | 3 x LED, green | | display mode | 3 x LED, green | | switching status | 2 x LED, yellow | | function display | alphanumeric display, 4-digit | | measured values | alphanumeric display, 4-digit |
|
| Display unit | bar; psi; MPa |
| Remarks |
|---|
| Pack quantity | 1 pcs. |
| Electrical connection |
|---|
| Connection | Connector: 1 x M12; Contacts: gold-plated |