Product characteristics |
---|
Output signal | switching signal; IO-Link; (configurable) |
Measuring range | 0…250 bar | 0…3625 psi | 0…25 MPa |
|
Process connection | threaded connection G 1/4 external thread internal thread:M5 |
Application |
---|
Application | for mobile applications |
Media | liquids and gases |
Conditionally suitable for | use in gases at pressures > 25 bar only on request |
Medium temperature [°C] | -25…90 |
Min. bursting pressure | |
Pressure rating | |
Type of pressure | relative pressure |
Electrical data |
---|
Operating voltage [V] | 9.6…36 DC; (communication mode: 18…32) |
Current consumption [mA] | < 45 |
Min. insulation resistance [MΩ] | 100; (500 V DC) |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 0.3 |
Inputs / outputs |
---|
Number of inputs and outputs | Number of digital outputs: 2 |
Outputs |
---|
Total number of outputs | 2 |
Output signal | switching signal; IO-Link; (configurable) |
Electrical design | PNP |
Number of digital outputs | 2 |
Output function | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 250 |
Switching frequency DC [Hz] | 170 |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Measuring/setting range |
---|
Measuring range | 0…250 bar | 0…3625 psi | 0…25 MPa |
|
Set point SP | 2…250 bar | 40…3620 psi | 0.2…25 MPa |
|
Reset point rP | 1…249 bar | 20…3600 psi | 0.1…24.9 MPa |
|
In steps of | |
Factory setting | | SP1 = 63 bar | rP1 = 58 bar | | SP2 = 188 bar | rP2 = 183 bar | | OUT1 = Hno | OUT2 = Hno |
|
Accuracy / deviations |
---|
Switch point accuracy [% of the span] | < ± 0,5 |
Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) |
Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
Hysteresis deviation [% of the span] | < ± 0,1 |
Long-term stability [% of the span] | < ± 0,1; (per year) |
Temperature coefficient zero point [% of the span / 10 K] | 0,2; (0…80 °C) |
Temperature coefficient span [% of the span / 10 K] | 0,2; (0…80 °C) |
Response times |
---|
Response time [ms] | < 3 |
Damping for the switching output dAP in steps [s] | 0,003 – 0,006 – 0,010 – 0,017 – 0,060 – 0,125 – 0,250 – 0,500 |
Interfaces |
---|
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.0 |
Profiles | no profile |
SIO mode | yes |
Required master port type | A |
Process data analogue | 1 |
Process data binary | 2 |
Min. process cycle time [ms] | 2.3 |
Supported DeviceIDs | Type of operation | DeviceID | Default | 3 |
|
Operating conditions |
---|
Ambient temperature [°C] | -25…85 |
Storage temperature [°C] | -40…100 |
Protection | IP 68; (7 days / 1 m water depth / 0.1 bar) |
Mechanical data |
---|
Weight [g] | 218 |
Materials | stainless steel (1.4301 / 304); FKM; EPDM/X; PA |
Materials (wetted parts) | stainless steel (1.4305 / 303); ceramics; FKM |
Min. pressure cycles | 100 million |
Process connection | threaded connection G 1/4 external thread internal thread:M5 |
Restrictor element integrated | yes |
Displays / operating elements |
---|
Display | operation | 2 x LED, green | switching status | 2 x LED, yellow |
|
Teach function | yes |
Remarks |
---|
Pack quantity | 1 pcs. |
Electrical connection |
---|
Connection | Connector: 1 x M12 |