| Product characteristics |
|---|
| Output signal | switching signal |
| Measuring range | |
| Process connection | threaded connection G 1/8 internal thread |
| Application |
|---|
| Special feature | Gold-plated contacts |
| Application | for industrial applications |
| Media | compressed air |
| Conditionally suitable for | other media on request |
| Medium temperature [°C] | 0…60 |
| Min. bursting pressure [bar] | 30 |
| Pressure rating [bar] | 20 |
| Type of pressure | relative pressure; vacuum |
| Electrical data |
|---|
| Operating voltage [V] | 18…32 DC; (according to EN 50178 SELV/PELV) |
| Current consumption [mA] | < 50 |
| Min. insulation resistance [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Overvoltage protection | yes; (< 40 V) |
| Power-on delay time [s] | 0.3 |
| Integrated watchdog | yes |
| Inputs / outputs |
|---|
| Number of inputs and outputs | Number of digital outputs: 2 |
| Outputs |
|---|
| Total number of outputs | 2 |
| Output signal | switching signal |
| Electrical design | NPN |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] | 2 |
| Permanent current rating of switching output DC [mA] | 100 |
| Switching frequency DC [Hz] | < 200 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Measuring/setting range |
|---|
| Measuring range | |
| Set point SP [bar] | -0.98…1 |
| Reset point rP [bar] | -0.99…0.99 |
| In steps of [bar] | 0.01 |
| Accuracy / deviations |
|---|
| Switch point accuracy [% of the span] | < ± 0,5 |
| Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) |
| Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
| Hysteresis deviation [% of the span] | < ± 0,25 |
| Long-term stability [% of the span] | < ± 0,05; (per 6 months) |
| Temperature coefficient zero point [% of the span / 10 K] | 0,2; (0…60 °C) |
| Temperature coefficient span [% of the span / 10 K] | 0,2; (0…60 °C) |
| Response times |
|---|
| Response time [ms] | < 2.5 |
| Delay time programmable dS, dr [s] | 0; 0,002…5 |
| Software / programming |
|---|
| Parameter setting options | hysteresis / window; normally open / normally closed; diagnostic function; switching logic; switch-on/switch-off delay; Damping; Display unit |
| Operating conditions |
|---|
| Ambient temperature [°C] | 0…70 |
| Storage temperature [°C] | -25…85 |
| Protection | IP 65 |
| Mechanical data |
|---|
| Weight [K40] | 85.5 |
| Materials | PBT; FKM; polyester |
| Materials (wetted parts) | brass; FKM; silicon (coated); PBT |
| Min. pressure cycles | 50 million |
| Process connection | threaded connection G 1/8 internal thread |
| Displays / operating elements |
|---|
| Display | | Display unit | 4 x LED, green | | switching status | 2 x LED, yellow | | function display | alphanumeric display, 4-digit | | measured values | alphanumeric display, 4-digit |
|
| Display unit | bar; kPa; psi; inHg |
| Accessories |
|---|
| Accessories (optional) | | mounting set for DIN rail: TH 35-7,5 / EN60715, E37340 | | Thread extension: 1/8″, E30075 | | push-in air fitting for tube: Ø 6 mm, E30076 | | push-in air fitting for tube: Ø 8 mm, E30077 |
|
| Remarks |
|---|
| Pack quantity | 1 pcs. |
| Electrical connection |
|---|
| Connection | Connector: 1 x M8; Contacts: gold-plated |