Product characteristics |
---|
Output signal | switching signal; analogue signal; IO-Link; (configurable) |
Measuring range | -1…1 bar | -1000…1000 mbar | -14.6…14.6 psi | -29.4…29.4 inHg | -100…100 kPa |
|
Process connection | threaded connection G 1/8 internal thread internal thread:M5 |
Application |
---|
Special feature | Gold-plated contacts |
Application | for industrial applications |
Conditionally suitable for | other media on request |
Medium temperature [°C] | 0…60 |
Min. bursting pressure | 30 bar | 435 psi | 886 inHg | 3000 kPa |
|
Note on min. burst pressure | max. overpressure on second pressure connection: 12 bar / 1200 kPa / 174 PSI / 354,4 inHg / 1,2 MPa |
|
Pressure rating | 20 bar | 290 psi | 591 inHg | 2000 kPa |
|
Vacuum resistance [mbar] | -1000 |
Type of pressure | relative pressure; differential pressure; vacuum |
Electrical data |
---|
Operating voltage [V] | 18…32 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA] | < 50 |
Min. insulation resistance [MΩ] | 100; (500 V DC) |
Protection class | III |
Reverse polarity protection | yes |
Overvoltage protection | yes; (< 40 V) |
Power-on delay time [s] | 0.5 |
Integrated watchdog | yes |
Inputs / outputs |
---|
Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
Outputs |
---|
Total number of outputs | 2 |
Output signal | switching signal; analogue signal; IO-Link; (configurable) |
Electrical design | PNP |
Number of digital outputs | 1 |
Output function | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 100 |
Switching frequency DC [Hz] | < 100 |
Number of analogue outputs | 1 |
Analogue current output [mA] | 4…20 |
Max. load [Ω] | 500 |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Measuring/setting range |
---|
Measuring range | -1…1 bar | -1000…1000 mbar | -14.6…14.6 psi | -29.4…29.4 inHg | -100…100 kPa |
|
Set point SP | -0.98…1 bar | -14.2…14.6 psi | -28.8…29.4 inHg | -98…100 kPa |
|
Reset point rP | -0.99…0.99 bar | -14.4…14.4 psi | -29.1…29.1 inHg | -99…99 kPa |
|
In steps of | 0.01 bar | 0.2 psi | 0.3 inHg | 1 kPa |
|
Accuracy / deviations |
---|
Switch point accuracy [% of the span] | < ± 0,5 |
Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) |
Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
Hysteresis deviation [% of the span] | < ± 0,25 |
Long-term stability [% of the span] | < ± 0,05; (per 6 months) |
Temperature coefficient zero point [% of the span / 10 K] | 0,2; (0…60 °C) |
Temperature coefficient span [% of the span / 10 K] | 0,2; (0…60 °C) |
Response times |
---|
Response time [ms] | < 6 |
Delay time programmable dS, dr [s] | 0; 0,002…5 |
Step response time analogue output [ms] | 6 |
Software / programming |
---|
Parameter setting options | hysteresis / window; normally open / normally closed; analogue output; IO-Link; switching logic; switch-on/switch-off delay; Damping; Display unit |
Interfaces |
---|
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
SDCI standard | IEC 61131-9 FDIS |
Profiles | Smart Sensor: Process Data Variable; Device Identification |
SIO mode | yes |
Required master port type | A |
Process data analogue | 1 |
Process data binary | 2 |
Min. process cycle time [ms] | 2.3 |
Supported DeviceIDs | Type of operation | DeviceID | Default | 366 |
|
Operating conditions |
---|
Ambient temperature [°C] | 0…70 |
Storage temperature [°C] | -25…85 |
Protection | IP 65 |
Mechanical data |
---|
Weight [g] | 86.5 |
Materials | PBT; FKM; polyester |
Materials (wetted parts) | brass; FKM; silicon (coated); PBT |
Min. pressure cycles | 50 million |
Process connection | threaded connection G 1/8 internal thread internal thread:M5 |
Displays / operating elements |
---|
Display | Display unit | 4 x LED, green | switching status | 1 x LED, yellow | function display | alphanumeric display, 4-digit | measured values | alphanumeric display, 4-digit |
|
Display unit | bar; kPa; psi; inHg |
Remarks |
---|
Pack quantity | 1 pcs. |
Electrical connection |
---|
Connection | Connector: 1 x M8; Contacts: gold-plated |