| Product characteristics |
|---|
| Output signal | switching signal; analogue signal; IO-Link; (configurable) |
| Measuring range | | -1…10 bar | -15…145 psi | -30…296 inHg | -100…1000 kPa |
|
| Process connection | threaded connection G 1/8 internal thread internal thread:M5 |
| Application |
|---|
| Special feature | Gold-plated contacts |
| Application | for industrial applications |
| Conditionally suitable for | other media on request |
| Medium temperature [°C] | 0…60 |
| Min. bursting pressure | | 30 bar | 435 psi | 886 inHg | 3000 kPa |
|
| Note on min. burst pressure | | max. overpressure on second pressure connection: 12 bar / 1200 kPa / 174 PSI / 354,4 inHg / 1,2 MPa |
|
| Pressure rating | | 20 bar | 290 psi | 591 inHg | 2000 kPa |
|
| Vacuum resistance [mbar] | -1000 |
| Type of pressure | relative pressure; differential pressure; vacuum |
| Electrical data |
|---|
| Operating voltage [V] | 18…32 DC; (according to EN 50178 SELV/PELV) |
| Current consumption [mA] | < 50 |
| Min. insulation resistance [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Overvoltage protection | yes; (< 40 V) |
| Power-on delay time [s] | 0.5 |
| Integrated watchdog | yes |
| Inputs / outputs |
|---|
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
| Outputs |
|---|
| Total number of outputs | 2 |
| Output signal | switching signal; analogue signal; IO-Link; (configurable) |
| Electrical design | PNP |
| Number of digital outputs | 1 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] | 2 |
| Permanent current rating of switching output DC [mA] | 100 |
| Switching frequency DC [Hz] | < 100 |
| Number of analogue outputs | 1 |
| Analogue current output [mA] | 4…20 |
| Max. load [Ω] | 500 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Measuring/setting range |
|---|
| Measuring range | | -1…10 bar | -15…145 psi | -30…296 inHg | -100…1000 kPa |
|
| Set point SP | | -0.9…10 bar | -13…145 psi | -26…296 inHg | -90…1000 kPa |
|
| Reset point rP | | -0.95…9.95 bar | -14…144 psi | -28…294 inHg | -95…995 kPa |
|
| In steps of | | 0.05 bar | 1 psi | 2 inHg | 5 kPa |
|
| Accuracy / deviations |
|---|
| Switch point accuracy [% of the span] | < ± 0,5 |
| Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) |
| Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
| Hysteresis deviation [% of the span] | < ± 0,25 |
| Long-term stability [% of the span] | < ± 0,05; (per 6 months) |
| Temperature coefficient zero point [% of the span / 10 K] | 0,2; (0…60 °C) |
| Temperature coefficient span [% of the span / 10 K] | 0,2; (0…60 °C) |
| Response times |
|---|
| Response time [ms] | < 6 |
| Delay time programmable dS, dr [s] | 0; 0,002…5 |
| Step response time analogue output [ms] | 6 |
| Software / programming |
|---|
| Parameter setting options | hysteresis / window; normally open / normally closed; analogue output; IO-Link; switching logic; switch-on/switch-off delay; Damping; Display unit |
| Interfaces |
|---|
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 FDIS |
| Profiles | Smart Sensor: Process Data Variable; Device Identification |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 1 |
| Process data binary | 2 |
| Min. process cycle time [ms] | 2.3 |
| Supported DeviceIDs | | Type of operation | DeviceID | | Default | 367 |
|
| Operating conditions |
|---|
| Ambient temperature [°C] | 0…70 |
| Storage temperature [°C] | -25…85 |
| Protection | IP 65 |
| Mechanical data |
|---|
| Weight [g] | 87 |
| Materials | PBT; FKM; polyester |
| Materials (wetted parts) | brass; FKM; silicon (coated); PBT |
| Min. pressure cycles | 50 million |
| Process connection | threaded connection G 1/8 internal thread internal thread:M5 |
| Displays / operating elements |
|---|
| Display | | Display unit | 4 x LED, green | | switching status | 1 x LED, yellow | | function display | alphanumeric display, 4-digit | | measured values | alphanumeric display, 4-digit |
|
| Display unit | bar; kPa; psi; inHg |
| Remarks |
|---|
| Pack quantity | 1 pcs. |
| Electrical connection |
|---|
| Connection | Connector: 1 x M8; Contacts: gold-plated |