Product characteristics |
---|
Output signal | switching signal |
Measuring range | -1…10 bar | -15…145 psi | -30…296 inHg | -100…1000 kPa |
|
Process connection | threaded connection G 1/8 internal thread |
Application |
---|
Special feature | Gold-plated contacts |
Application | for industrial applications |
Media | compressed air |
Conditionally suitable for | other media on request |
Medium temperature [°C] | 0…60 |
Min. bursting pressure | 30 bar | 435 psi | 886 inHg | 3000 kPa |
|
Pressure rating | 20 bar | 290 psi | 591 inHg | 2000 kPa |
|
Vacuum resistance [mbar] | -1000 |
Type of pressure | relative pressure; vacuum |
Electrical data |
---|
Operating voltage [V] | 18…32 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA] | < 50 |
Min. insulation resistance [MΩ] | 100; (500 V DC) |
Protection class | III |
Reverse polarity protection | yes |
Overvoltage protection | yes; (< 40 V) |
Power-on delay time [s] | 0.3 |
Integrated watchdog | yes |
Inputs / outputs |
---|
Number of inputs and outputs | Number of digital outputs: 2 |
Outputs |
---|
Total number of outputs | 2 |
Output signal | switching signal |
Electrical design | PNP |
Number of digital outputs | 2 |
Output function | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 100 |
Switching frequency DC [Hz] | < 200 |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Measuring/setting range |
---|
Measuring range | -1…10 bar | -15…145 psi | -30…296 inHg | -100…1000 kPa |
|
Set point SP | -0.9…10 bar | -13…145 psi | -26…296 inHg | -90…1000 kPa |
|
Reset point rP | -0.95…9.95 bar | -14…144 psi | -28…294 inHg | -95…995 kPa |
|
In steps of | 0.05 bar | 1 psi | 2 inHg | 5 kPa |
|
Accuracy / deviations |
---|
Switch point accuracy [% of the span] | < ± 0,5 |
Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) |
Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
Hysteresis deviation [% of the span] | < ± 0,25 |
Long-term stability [% of the span] | < ± 0,05; (per 6 months) |
Temperature coefficient zero point [% of the span / 10 K] | 0,2; (0…60 °C) |
Temperature coefficient span [% of the span / 10 K] | 0,2; (0…60 °C) |
Response times |
---|
Response time [ms] | < 2.5 |
Delay time programmable dS, dr [s] | 0; 0,002…5 |
Software / programming |
---|
Parameter setting options | hysteresis / window; normally open / normally closed; diagnostic function; switching logic; switch-on/switch-off delay; Damping; Display unit |
Operating conditions |
---|
Ambient temperature [°C] | 0…70 |
Storage temperature [°C] | -25…85 |
Protection | IP 65 |
Mechanical data |
---|
Weight [g] | 84.5 |
Materials | PBT; FKM; polyester |
Materials (wetted parts) | brass; FKM; silicon (coated); PBT |
Min. pressure cycles | 50 million |
Process connection | threaded connection G 1/8 internal thread |
Displays / operating elements |
---|
Display | Display unit | 4 x LED, green | switching status | 2 x LED, yellow | function display | alphanumeric display, 4-digit | measured values | alphanumeric display, 4-digit |
|
Display unit | bar; kPa; psi; inHg |
Accessories |
---|
Accessories (optional) | mounting set for DIN rail: TH 35-7,5 / EN60715, E37340 | Thread extension: 1/8″, E30075 | push-in air fitting for tube: Ø 6 mm, E30076 | push-in air fitting for tube: Ø 8 mm, E30077 |
|
Remarks |
---|
Pack quantity | 1 pcs. |
Electrical connection |
---|
Connection | Connector: 1 x M8; Contacts: gold-plated |