Product characteristics |
---|
Output signal | switching signal; IO-Link; (configurable) |
Measuring range | 0…400 bar | 0…5800 psi | 0…40 MPa |
|
Process connection | threaded connection 1/4″ NPT external thread internal thread:M5 |
Application |
---|
Measuring element | metallic thin film cell |
Application | for industrial applications |
Media | liquids and gases |
Medium temperature [°C] | -40…90 |
Min. bursting pressure | 1700 bar | 24655 psi | 170 MPa |
|
Pressure rating | 1000 bar | 14500 psi | 100 Mpa |
|
Note on pressure rating | |
Vacuum resistance [mbar] | -1000 |
Type of pressure | relative pressure |
MAWP (for applications according to CRN) [bar] | 840 |
Electrical data |
---|
Operating voltage [V] | 18…30 DC |
Current consumption [mA] | < 15 |
Min. insulation resistance [MΩ] | 100; (500 V DC) |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | < 0.3 |
Inputs / outputs |
---|
Number of inputs and outputs | Number of digital outputs: 2 |
Outputs |
---|
Total number of outputs | 2 |
Output signal | switching signal; IO-Link; (configurable) |
Electrical design | PNP/NPN |
Number of digital outputs | 2 |
Output function | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 100 |
Switching frequency DC [Hz] | < 170 |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Measuring/setting range |
---|
Measuring range | 0…400 bar | 0…5800 psi | 0…40 MPa |
|
Set point SP | 4…400 bar | 58…5802 psi | 0.4…40 MPa |
|
Reset point rP | 2…398 bar | 30…5773 psi | 0.2…39.8 MPa |
|
In steps of | |
Factory setting | SP1 = 100 bar | rP1 = 92 bar | ou1 = Hno; | SP2 = 300 bar | rP2 = 292 bar | ou2 = Hno; | dS1/dS2 = 0 ms | dr1/dr2 = 0 ms | | coF = 0 % | P-n = PnP | dAP= 60 ms |
|
Accuracy / deviations |
---|
Switch point accuracy [% of the span] | < ± 0,5 (nach DIN EN 61298-2) |
Repeatability [% of the span] | < ± 0,05; (with temperature fluctuations < 10 K) |
Characteristics deviation [% of the span] | < ± 0,5 (nach DIN EN 61298-2); (incl. drift when overtightened, zero point and span error, non-linearity, hysteresis) |
Linearity deviation [% of the span] | < ± 0,1 (BFSL) / < ± 0,2 (LS) |
Hysteresis deviation [% of the span] | < ± 0,2 |
Long-term stability [% of the span] | < ± 0,1; (per 6 months) |
Temperature coefficient zero point [% of the span / 10 K] | < 0,1 (-25…90 °C) / < 0,2 (-40…-25 °C) |
Temperature coefficient span [% of the span / 10 K] | < 0,1 (-25…90 °C) / < 0,2 (-40…-25 °C) |
Response times |
---|
Response time [ms] | < 3 |
Software / programming |
---|
Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping |
Interfaces |
---|
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
SDCI standard | IEC 61131-9 |
Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO mode | yes |
Required master port type | A |
Process data analogue | 2 |
Process data binary | 2 |
Min. process cycle time [ms] | 5 |
Supported DeviceIDs | Type of operation | DeviceID | Default | 851 |
|
Operating conditions |
---|
Ambient temperature [°C] | -40…90 |
Storage temperature [°C] | -40…100 |
Protection | IP 67; IP 69K |
Mechanical data |
---|
Weight [g] | 65 |
Materials | 1.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L); PEI |
Materials (wetted parts) | stainless steel (1.4305 / 303); 1.4542 (17-4 PH / 630) |
Min. pressure cycles | 60 million; (at 1.2 times nominal pressure) |
Tightening torque [Nm] | 50; (recommended tightening torque; depends on lubrication, seal and pressure rating) |
Process connection | threaded connection 1/4″ NPT external thread internal thread:M5 |
Restrictor element integrated | yes |
Remarks |
---|
Remarks | BFSL = Best Fit Straight Line | LS = limit value setting |
|
Pack quantity | 1 pcs. |
Electrical connection |
---|
Connection | Connector: 1 x M12 |