| Product characteristics |
|---|
| Output signal | switching signal; IO-Link; (configurable) |
| Measuring range | | 0…400 bar | 0…5800 psi | 0…40 MPa |
|
| Process connection | flange internal thread:G 1/4; internal thread:M6 |
| Application |
|---|
| Special feature | Gold-plated contacts |
| Design | with flange adapter |
| Media | liquids and gases |
| Conditionally suitable for | use in gases at pressures > 25 bar only on request |
| Medium temperature [°C] | -25…80 |
| Min. bursting pressure | | 1000 bar | 14500 psi | 100 MPa |
|
| Pressure rating | |
| Type of pressure | relative pressure |
| Electrical data |
|---|
| Operating voltage [V] | 18…36 DC; (according to EN 50178 SELV/PELV) |
| Current consumption [mA] | < 50 |
| Min. insulation resistance [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Overvoltage protection | yes; (< 40 V) |
| Power-on delay time [s] | 0.3 |
| Integrated watchdog | yes |
| Inputs / outputs |
|---|
| Number of inputs and outputs | Number of digital outputs: 2 |
| Outputs |
|---|
| Total number of outputs | 2 |
| Output signal | switching signal; IO-Link; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] | 2 |
| Permanent current rating of switching output DC [mA] | 250 |
| Switching frequency DC [Hz] | < 170 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Measuring/setting range |
|---|
| Measuring range | | 0…400 bar | 0…5800 psi | 0…40 MPa |
|
| Set point SP | | 4…400 bar | 60…5790 psi | 0.4…40 MPa |
|
| Reset point rP | | 2…398 bar | 30…5760 psi | 0.2…39.8 MPa |
|
| In steps of | |
| Factory setting | | SP1 = 100 bar | rP1 = 92 bar | | SP2 = 300 bar | rP2 = 292 bar |
|
| Accuracy / deviations |
|---|
| Switch point accuracy [% of the span] | < ± 0,5 |
| Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) |
| Characteristics deviation [% of the span] | < ± 0,5; (linearity, incl. hysteresis and repeatability limit value setting to DIN 16086) |
| Hysteresis deviation [% of the span] | < ± 0,25 |
| Long-term stability [% of the span] | < ± 0,05; (per 6 months) |
| Temperature coefficient zero point [% of the span / 10 K] | 0,2; (0…80 °C) |
| Temperature coefficient span [% of the span / 10 K] | 0,2; (0…80 °C) |
| Response times |
|---|
| Delay time programmable dS, dr [s] | 0; 0,2…50 |
| Software / programming |
|---|
| Parameter setting options | hysteresis / window; normally open / normally closed; diagnostic function; switching logic; switch-on/switch-off delay; Damping; Display unit |
| Interfaces |
|---|
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 CDV |
| Profiles | no profile |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 1 |
| Process data binary | 2 |
| Min. process cycle time [ms] | 2.3 |
| Supported DeviceIDs | | Type of operation | DeviceID | | Default | 307 |
|
| Operating conditions |
|---|
| Ambient temperature [°C] | -20…80 |
| Storage temperature [°C] | -40…100 |
| Protection | IP 67 |
| Mechanical data |
|---|
| Weight [g] | 383 |
| Materials | stainless steel (1.4301 / 304); PC; PBT; PEI; FKM |
| Materials (wetted parts) | steel (1.4104 / 430F); ceramics; FKM |
| Min. pressure cycles | 50 million |
| Process connection | flange internal thread:G 1/4; internal thread:M6 |
| Restrictor element integrated | yes |
| Displays / operating elements |
|---|
| Display | | Display unit | 3 x LED, green | | switching status | 2 x LED, yellow | | function display | alphanumeric display, 4-digit | | measured values | alphanumeric display, 4-digit |
|
| Remarks |
|---|
| Pack quantity | 1 pcs. |
| Electrical connection |
|---|
| Connector: 1 x M12; Contacts: gold-plated |