|  Product characteristics | 
|---|
|  Output signal |  switching signal | 
|  Measuring range | |  0…250 bar |  0…3625 psi |  0…25 MPa |  
  | 
|  Process connection |  threaded connection G 1/4 internal thread | 
|  Application | 
|---|
|  Special feature |  Gold-plated contacts | 
|  Media |  liquids and gases | 
|  Conditionally suitable for |  For gaseous media the application is limited to max. 25 bar. | 
|  Medium temperature [°C] |  -25…80 | 
|  Min. bursting pressure |  | 
|  Pressure rating |  | 
|  Type of pressure |  relative pressure | 
|  Electrical data | 
|---|
|  Operating voltage [V] |  18…36 DC; (according to EN 50178 SELV/PELV) | 
|  Current consumption [mA] |  < 50 | 
|  Min. insulation resistance [MΩ] |  100; (500 V DC) | 
|  Protection class |  III | 
|  Reverse polarity protection |  yes | 
|  Overvoltage protection |  yes; (< 40 V) | 
|  Power-on delay time [s] |  0.3 | 
|  Integrated watchdog |  yes | 
|  Inputs / outputs | 
|---|
|  Number of inputs and outputs |  Number of digital outputs: 2 | 
|  Outputs | 
|---|
|  Total number of outputs |  2 | 
|  Output signal |  switching signal | 
|  Electrical design |  PNP/NPN | 
|  Number of digital outputs |  2 | 
|  Output function |  normally open / normally closed; (parameterisable) | 
|  Max. voltage drop switching output DC [V] |  2 | 
|  Permanent current rating of switching output DC [mA] |  250 | 
|  Switching frequency DC [Hz] |  < 170 | 
|  Short-circuit protection |  yes | 
|  Type of short-circuit protection |  pulsed | 
|  Measuring/setting range | 
|---|
|  Measuring range | |  0…250 bar |  0…3625 psi |  0…25 MPa |  
  | 
|  Set point SP | |  2…250 bar |  40…3620 psi |  0.2…25 MPa |  
  | 
|  Reset point rP | |  1…249 bar |  20…3600 psi |  0.1…24.9 MPa |  
  | 
|  In steps of |  | 
|  Accuracy / deviations | 
|---|
|  Switch point accuracy [% of the span] |  < ± 0,5 | 
|  Repeatability [% of the span] |  < ± 0,1; (with temperature fluctuations < 10 K) | 
|  Characteristics deviation [% of the span] |  < ± 0,5; (linearity, incl. hysteresis and repeatability limit value setting to DIN 16086) | 
|  Hysteresis deviation [% of the span] |  < ± 0,25 | 
|  Long-term stability [% of the span] |  < ± 0,05; (per 6 months) | 
|  Temperature coefficient zero point [% of the span / 10 K] |  0,2; (0…80 °C) | 
|  Temperature coefficient span [% of the span / 10 K] |  0,2; (0…80 °C) | 
|  Response times | 
|---|
|  Delay time programmable dS, dr [s] |  0; 0,2…50 | 
|  Software / programming | 
|---|
|  Parameter setting options |  hysteresis / window; normally open / normally closed; diagnostic function; switching logic; switch-on/switch-off delay; Damping; Display unit | 
|  Operating conditions | 
|---|
|  Ambient temperature [°C] |  -20…80 | 
|  Storage temperature [°C] |  -40…100 | 
|  Protection |  IP 67 | 
|  Mechanical data | 
|---|
|  Weight [g] |  261 | 
|  Materials |  stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); PC; PBT; PEI; FKM | 
|  Materials (wetted parts) |  stainless steel (1.4305 / 303); ceramics; FKM | 
|  Min. pressure cycles |  100 million | 
|  Process connection |  threaded connection G 1/4 internal thread | 
|  Restrictor element integrated |  no (can be retrofitted) | 
|  Displays / operating elements | 
|---|
|  Display | |  Display unit |  3 x LED, green |  |  switching status |  2 x LED, yellow |  |  function display |  alphanumeric display, 4-digit |  |  measured values |  alphanumeric display, 4-digit |  
  | 
|  Remarks | 
|---|
|  Pack quantity |  1 pcs. | 
|  Electrical connection | 
|---|
 |  Connector: 1 x M12; Contacts: gold-plated |