| Product characteristics |
|---|
| Output signal | switching signal; analogue signal; (configurable) |
| Measuring range | | 0…400 bar | 0…5800 psi | 0…40 MPa |
|
| Process connection | homogeniser connection |
| Application |
|---|
| Special feature | Gold-plated contacts |
| Application | food and beverage industry |
| Conditionally suitable for | For gaseous media the application is limited to max. 25 bar. |
| Medium temperature [°C] | -10…140 |
| Min. bursting pressure | | 1000 bar | 14500 psi | 100 MPa |
|
| Pressure rating | |
| Type of pressure | relative pressure |
| Electrical data |
|---|
| Operating voltage [V] | 20…32 DC; (according to EN 50178 SELV/PELV) |
| Current consumption [mA] | < 65 |
| Min. insulation resistance [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | 0.2 |
| Integrated watchdog | yes |
| Inputs / outputs |
|---|
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Outputs |
|---|
| Total number of outputs | 2 |
| Output signal | switching signal; analogue signal; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] | 2 |
| Permanent current rating of switching output DC [mA] | 250 |
| Switching frequency DC [Hz] | < 170 |
| Number of analogue outputs | 1 |
| Analogue current output [mA] | 4…20; (scalable 1:4) |
| Max. load [Ω] | (Ub – 10 V) / 20 mA |
| Analogue voltage output [V] | 0…10; (scalable 1:4) |
| Min. load resistance [Ω] | 2000 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
| Measuring/setting range |
|---|
| Measuring range | | 0…400 bar | 0…5800 psi | 0…40 MPa |
|
| Set point SP | | 4…400 bar | 60…5800 psi | 0.4…40 MPa |
|
| Reset point rP | | 2…398 bar | 30…5770 psi | 0.2…39.8 MPa |
|
| Analogue start point | | 0…160 bar | 0…2320 psi | 0…16 MPa |
|
| Analogue end point | | 100…400 bar | 1450…5800 psi | 10…40 MPa |
|
| In steps of | |
| Factory setting | | SP1 = 100 bar | rP1 = 92 bar | | SP2 = 300 bar | rP2 = 292 bar | | ASP = 0 bar | AEP = 400 bar |
|
| Accuracy / deviations |
|---|
| Switch point accuracy [% of the span] | < ± 1,0 |
| Repeatability [% of the span] | < ± 0,25; (with temperature fluctuations < 10 K) |
| Characteristics deviation [% of the span] | < ± 1,0 |
| Temperature coefficient zero point [% of the span / 10 K] | < ± 0,3; (0…80 °C) |
| Temperature coefficient span [% of the span / 10 K] | < ± 0,3; (0…80 °C) |
| Response times |
|---|
| Response time [ms] | < 3 |
| Damping for the switching output dAP [s] | 0…4 |
| Damping for the analogue output dAA [s] | 0…4 |
| Max. response time analogue output [ms] | 3 |
| Software / programming |
|---|
| Parameter setting options | zero point; span |
| Operating conditions |
|---|
| Ambient temperature [°C] | -25…80 |
| Storage temperature [°C] | -40…100 |
| Protection | IP 67 |
| Mechanical data |
|---|
| Weight [g] | 1588.5 |
| Materials | stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); PC; PBT; PEI; FKM |
| Materials (wetted parts) | stainless steel |
| Min. pressure cycles | 1 million |
| Process connection | homogeniser connection |
| Displays / operating elements |
|---|
| Display | | Display unit | 3 x LED, green | | switching status | 2 x LED, yellow | | function display | alphanumeric display, 4-digit | | measured values | alphanumeric display, 4-digit |
|
| Remarks |
|---|
| Pack quantity | 1 pcs. |
| Electrical connection |
|---|
| Connection | Connector: 1 x M12; Contacts: gold-plated |