| Product characteristics | 
|---|
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | 
| Process connection | threaded connection M18 x 1,5 internal thread | 
| Application | 
|---|
| Special feature | Gold-plated contacts | 
| Media | water; glycol solutions; air; oils | 
| Note on media | | low-viscosity oils with viscosity: ≤ 40 mm²/s (104 °F) |  | high-viscosity oils with viscosity: > 40 mm²/s (104 °F) | 
 | 
| Medium temperature [°F] | -4…194 | 
| Pressure rating [bar] | 100 | 
| Pressure rating [psi] | 1450 | 
| Electrical data | 
|---|
| Operating voltage [V] | 18…30 DC | 
| Current consumption [mA] | < 100 | 
| Protection class | III | 
| Reverse polarity protection | yes | 
| Power-on delay time [s] | 10 | 
| Inputs / outputs | 
|---|
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | 
| Outputs | 
|---|
| Total number of outputs | 2 | 
| Output signal | switching signal; analogue signal; frequency signal; IO-Link; (configurable) | 
| Electrical design | PNP/NPN | 
| Number of digital outputs | 2 | 
| Output function | normally open / normally closed; (parameterisable) | 
| Max. voltage drop switching output DC [V] | 2.5 | 
| Permanent current rating of switching output DC [mA] | 250 | 
| Number of analogue outputs | 1 | 
| Analogue current output [mA] | 4…20; (scalable) | 
| Max. load [Ω] | 350 | 
| Short-circuit protection | yes | 
| Type of short-circuit protection | pulsed | 
| Overload protection | yes | 
| Frequency of the output [Hz] | 0…1000 | 
| Measuring/setting range | 
|---|
| Probe length L [mm] | 45 | 
| Operating mode | relative; absolutely liquid; absolutely gaseous; (absolute: reference measurement recommended) | 
| Note on factory setting |  | 
| Liquids | 
|---|
| Setting range [ft/s] | 0…19.5 | 
| Greatest sensitivity [ft/s] | 0.15…9.85 | 
| Gases | 
|---|
| Setting range [ft/s] | 0…656 | 
| Greatest sensitivity [ft/s] | 6…328 | 
| Temperature monitoring | 
|---|
| Measuring range [°F] | -4…194 | 
| Resolution [°F] | 0.5 | 
| Accuracy / deviations | 
|---|
| Flow monitoring | 
|---|
| Temperature drift [cm/s x 1/K] | 0,01 fps x 1/K (< 68 °F; > 158 °F) | 
| Temperature gradient [K/min] | 100 | 
| Accuracy | ± (7 % MW + 2 % MEW); (for relative mode in the range of maximum sensitivity under the following conditions :; water: 68…158 °F; inlet length: 5 ft; DN25 (DIN 2448); mounting position according to instructions; Accuracy can differ for other media and mounting positions.) | 
| Repeatability | 0,05 m/s; (water; flow velocity: 0,05…3 m/s) | 
| Temperature monitoring | 
|---|
| Temperature drift | ± 0,003 K/°F | 
| Accuracy [K] | ± 0,3 / ± 1; (water; flow velocity: 1…9,85 fps / air; flow velocity: > 32,8 fps) | 
| Response times | 
|---|
| Flow monitoring | 
|---|
| Response time [s] | 0.5; (T09; water; glycol: 0,8 s; air: 7 s; oil: 1,8 s; each T09) | 
| Temperature monitoring | 
|---|
| Dynamic response T05 / T09 [s] | 1,5 (T09); (water; flow velocity: 1…9,85 fps) | 
| Software / programming | 
|---|
| Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; current/frequency output; medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value colour | 
| Interfaces | 
|---|
| Communication interface | IO-Link | 
| Transmission type | COM2 (38,4 kBaud) | 
| IO-Link revision | 1.1 | 
| SDCI standard | IEC 61131-9 | 
| Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | 
| SIO mode | yes | 
| Required master port type | A | 
| Process data analogue | 2 | 
| Process data binary | 2 | 
| Min. process cycle time [ms] | 3 | 
| Supported DeviceIDs | | Type of operation | DeviceID |  | Factory setting / ModE = (REL) | 537 |  | ModE = (LIQU) | 544 |  | ModE = (GAS) | 551 | 
 | 
| Operating conditions | 
|---|
| Ambient temperature [°F] | -40…176 | 
| Storage temperature [°F] | -40…212 | 
| Protection | IP 65; IP 67 | 
| Mechanical data | 
|---|
| Weight [g] | 312.5 | 
| Materials | stainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PBT-GF20; PBT-GF30 | 
| Materials (wetted parts) | stainless steel (1.4404 / 316L); Gasket: FKM | 
| Process connection | threaded connection M18 x 1,5 internal thread | 
| Displays / operating elements | 
|---|
| Display | | Display unit | 6 x LED, green (%, fps, gpm, cfm, °F, 10³) |  | switching status | 2 x LED, yellow |  | measured values | alphanumeric display, red/green 4-digit | 
 | 
| Remarks | 
|---|
| Remarks | | MW = measured value |  | MEW = Final value of the measuring range | 
 | 
| Pack quantity | 1 pcs. | 
| Electrical connection | 
|---|
| Connection | Connector: 1 x M12; Contacts: gold-plated |