| Product characteristics | 
|---|
| Process connection | threaded connection G 1 internal thread | 
| Temperature monitoring | 
|---|
| Measuring range |  | 
| Application | 
|---|
| Special feature | Gold-plated contacts | 
| Media | Liquids; oil | 
| Note on media | | oil with viscosity: 68 mm²/s (40 °C) | 
 | 
| Medium temperature [°C] | -10…100 | 
| Pressure rating [bar] | 100 | 
| Pressure rating [Mpa] | 10 | 
| Note on pressure rating | | at medium temperature >70°C: 80 bar / 8 MPa | 
 | 
| Electrical data | 
|---|
| Operating voltage [V] | 18…30 DC; (according to EN 50178 SELV/PELV) | 
| Current consumption [mA] | < 50 | 
| Protection class | III | 
| Reverse polarity protection | yes | 
| Power-on delay time [s] | < 3 | 
| Outputs | 
|---|
| Total number of outputs | 2 | 
| Output signal | switching signal; analogue signal; frequency signal; IO-Link | 
| Output function | normally open / normally closed; (parameterisable) | 
| Max. voltage drop switching output DC [V] | 2 | 
| Max. current load per output [mA] | 150; (200: …60 °C; Ambient temperature; 250: …40 °C; Ambient temperature) | 
| Analogue current output [mA] | 4…20 | 
| Max. load [Ω] | 500 | 
| Short-circuit protection | yes | 
| Overload protection | yes | 
| Frequency of the output [Hz] | 0…10000 | 
| Measuring/setting range | 
|---|
| Measuring range | | 2…100 l/min | 0.12…6 m³/h | 32…1586 gph | 0.55…26.4 gpm | 
 | 
| Display range | | 0…120 l/min | 0…7.2 m³/h | 0…1902 gph | 0…31.7 gpm | 
 | 
| Resolution | | 0.1 l/min | 0.01 m³/h | 1 gph | 0.01 gpm | 
 | 
| Set point SP | | 0.7…100 l/min | 0.04…6 m³/h | 10…1586 gph | 0.15…26.4 gpm | 
 | 
| Reset point rP | | 0…99.3 l/min | 0…5.96 m³/h | 0…1574 gph | 0…26.25 gpm | 
 | 
| Frequency end point, FEP | | 6.7…100 l/min | 0.4…6 m³/h | 106…1586 gph | 1.75…26.4 gpm | 
 | 
| In steps of | | 0.1 l/min | 0.01 m³/h | 2 gph | 0.05 gpm | 
 | 
| Frequency at the end point FRP [Hz] | 10…10000 | 
| In steps of [Hz] | 10 | 
| Measuring dynamics | 1:50 | 
| In steps of | 10 Hz | 
| Temperature monitoring | 
|---|
| Measuring range |  | 
| Display range | | -32…122 °C | -25.6…251.6 °F | 
 | 
| Resolution |  | 
| Set point SP |  | 
| Reset point rP |  | 
| In steps of |  | 
| Frequency start point, FSP |  | 
| Frequency end point, FEP |  | 
| Frequency at the end point FRP [Hz] | 10…10000 | 
| Accuracy / deviations | 
|---|
| Flow monitoring | 
|---|
| Accuracy (in the measuring range) | ± 5 % MEW; (Q > 1 l/min; 20…70 °C Medium temperature) | 
| Repeatability | ± 1 % MEW | 
| Temperature monitoring | 
|---|
| Temperature drift | 0,029 °C / K | 
| Accuracy [K] | 3 K (25°C; Q > 1 l/min) | 
| Response times | 
|---|
| Flow monitoring | 
|---|
| Response time [s] | 0.01 | 
| Damping for the switching output dAP [s] | 0…5 | 
| In steps of [s] | 0.1 | 
| Damping for the analogue output dAA [s] | 0…5 | 
| In steps of [s] | 0.1 | 
| Temperature monitoring | 
|---|
| Dynamic response T05 / T09 [s] | T09 = 120 (Q > 1 l/min) | 
| Software / programming | 
|---|
| Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; current/frequency output; damping for the switching output / analogue output; display can be rotated and switched off; standard unit of measurement; process value colour; calibration factor | 
| Interfaces | 
|---|
| Communication interface | IO-Link | 
| Transmission type | COM2 (38,4 kBaud) | 
| IO-Link revision | 1.1 | 
| SDCI standard | IEC 61131-9 CDV | 
| Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | 
| SIO mode | yes | 
| Required master port type | A | 
| Process data analogue | 2 | 
| Process data binary | 2 | 
| Min. process cycle time [ms] | 3.2 | 
| Supported DeviceIDs | | Type of operation | DeviceID |  | Default | 1046 | 
 | 
| Operating conditions | 
|---|
| Ambient temperature [°C] | 0…60 | 
| Note on ambient temperature | | medium temperature < 80 °C |  | medium temperature < 100 °C: 0…40 °C | 
 | 
| Storage temperature [°C] | -15…80 | 
| Protection | IP 65; IP 67 | 
| Mechanical data | 
|---|
| Weight [g] | 1586 | 
| Materials | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC; brass chemically nickel-plated | 
| Materials (wetted parts) | stainless steel (1.4401 / 316); stainless steel (1.4404 / 316L); brass (2.0371); brass chemically nickel-plated; PPS; O-ring: FKM | 
| Process connection | threaded connection G 1 internal thread | 
| Switching cycles mechanical | 10 million | 
| Displays / operating elements | 
|---|
| Display | | Display unit | 6 x LED, green |  | switching status | 2 x LED, yellow |  | measured values | alphanumeric display, red/green alternating indication 4-digit |  | programming | alphanumeric display, 4-digit | 
 | 
| Remarks | 
|---|
| Remarks | | Recommendation: use a 200-micron filter. |  | All data refer to oil with the following nominal viscosity: |  | 68 mm²/s, 40 °C |  | MW = measured value |  | MEW = Final value of the measuring range | 
 | 
| Pack quantity | 1 pcs. | 
| Electrical connection | 
|---|
| Connection | Connector: 1 x M12; Contacts: gold-plated |