Product characteristics | |||
---|---|---|---|
Number of inputs and outputs | Number of digital outputs: 1 | ||
Process connection | M18 x 1,5 internal thread | ||
Application | |||
Media | Liquids; Gases | ||
Medium temperature [°C] | -25…80 | ||
Pressure rating [bar] | 30 | ||
Liquids | |||
Medium temperature [°C] | -25…80 | ||
Gases | |||
Medium temperature [°C] | -25…80 | ||
Electrical data | |||
Operating voltage [V] | 19…36 DC | ||
Current consumption [mA] | < 60 | ||
Protection class | III | ||
Reverse polarity protection | yes | ||
Power-on delay time [s] | 10 | ||
Inputs / outputs | |||
Number of inputs and outputs | Number of digital outputs: 1 | ||
Outputs | |||
Total number of outputs | 1 | ||
Output signal | switching signal | ||
Electrical design | PNP | ||
Number of digital outputs | 1 | ||
Output function | normally open / normally closed; (parameterisable) | ||
Max. voltage drop switching output DC [V] | 2.5 | ||
Permanent current rating of switching output DC [mA] | 250 | ||
Short-circuit protection | yes | ||
Type of short-circuit protection | pulsed | ||
Overload protection | yes | ||
Measuring/setting range | |||
Probe length L [mm] | 45 | ||
Liquids | |||
Setting range [cm/s] | 3…300 | ||
Greatest sensitivity [cm/s] | 3…100 | ||
Gases | |||
Setting range [cm/s] | 200…3000 | ||
Greatest sensitivity [cm/s] | 200…800 | ||
Accuracy / deviations | |||
Repeatability [cm/s] | 1…5 | ||
Note on repeatability |
| ||
Temperature drift [cm/s x 1/K] | 0.1; (for water 5…100 cm/s; 10…70 °C) | ||
Temperature gradient [K/min] | 300 | ||
Switch point accuracy [cm/s] | ± 2…± 10; (for water 5…100 cm/s; 25 °C; Factory setting) | ||
Hysteresis [cm/s] | 2…5; (for water 5…100 cm/s; 25 °C; Factory setting) | ||
Response times | |||
Response time [s] | 1…10 | ||
Liquids | |||
Response time [s] | 1…10 | ||
Gases | |||
Response time [s] | 1…10 | ||
Software / programming | |||
Adjustment of the switch point | pushbutton | ||
Operating conditions | |||
Ambient temperature [°C] | -25…80 | ||
Storage temperature [°C] | -25…100 | ||
Protection | IP 67 | ||
Mechanical data | |||
Weight [g] | 246 | ||
Dimensions [mm] | M18 x 1.5 | ||
Thread designation | M18 x 1.5 | ||
Materials | stainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PC; PBT-GF20; EPDM/X | ||
Materials (wetted parts) | stainless steel (1.4404 / 316L); O-ring: FKM 80 Shore A | ||
Process connection | M18 x 1,5 internal thread | ||
Displays / operating elements | |||
Display |
| ||
Remarks | |||
Pack quantity | 1 pcs. | ||
Electrical connection | |||
Connection | Connector: 1 x M12 |
Cảm biến lưu lượng IFM SI5000 30 bar
13.357.000 ₫
SKU: SI5000
Hãng sản xuất: IFM
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng từ: CO/CQ, hóa đơn VAT
Thông tin bổ sung
Thương hiệu | |
---|---|
Thời gian bảo hành | 5 Năm |
Ngõ ra | NC, NO, PNP |
Yêu cầu tư vấn | 0983 995 440(Call/Zalo) |
Khu vực Miền Nam
Khu vực Miền Bắc
Khu vực Miền Trung
Dịch vụ kỹ thuật/Bảo hành
Email liên hệ
Dịch vụ cung ứng sản phẩm
Vì sản phẩm đa dạng, nếu Quý khách chưa tìm được. Vui lòng liên hệ để được hỗ trợ.
Tư vấn lựa chọn hoặc chuyển đổi
Nhập khẩu thiết bị theo yêu cầu