| Product characteristics |
|---|
| Number of inputs and outputs | Number of digital outputs: 1 |
| Process connection | M18 x 1,5 internal thread |
| Application |
|---|
| Media | Liquids; Gases |
| Medium temperature [°C] | -25…80 |
| Pressure rating [bar] | 300 |
| MAWP (for applications according to CRN) [bar] | 208 |
| Liquids |
|---|
| Medium temperature [°C] | -25…80 |
| Gases |
|---|
| Medium temperature [°C] | -25…80 |
| Electrical data |
|---|
| Operating voltage [V] | 18…36 DC |
| Current consumption [mA] | < 60 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | 10 |
| Inputs / outputs |
|---|
| Number of inputs and outputs | Number of digital outputs: 1 |
| Outputs |
|---|
| Total number of outputs | 1 |
| Output signal | switching signal; IO-Link; (configurable) |
| Electrical design | PNP |
| Number of digital outputs | 1 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] | 2.5 |
| Permanent current rating of switching output DC [mA] | 250 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
| Measuring/setting range |
|---|
| Liquids |
|---|
| Setting range [cm/s] | 3…300 |
| Greatest sensitivity [cm/s] | 3…100 |
| Gases |
|---|
| Setting range [cm/s] | 200…3000 |
| Greatest sensitivity [cm/s] | 200…800 |
| Accuracy / deviations |
|---|
| Repeatability [cm/s] | 1…5 |
| Note on repeatability | | for water 5…100 cm/s; 25 °C | | Factory setting |
|
| Temperature drift [cm/s x 1/K] | 0.1; (for water 5…100 cm/s; 10…70 °C) |
| Temperature gradient [K/min] | 300 |
| Switch point accuracy [cm/s] | ± 2…± 10; (for water 5…100 cm/s; 25 °C; Factory setting) |
| Hysteresis [cm/s] | 2…5; (for water 5…100 cm/s; 25 °C; Factory setting) |
| Response times |
|---|
| Liquids |
|---|
| Response time [s] | 1…2; (for a temperature gradient: 1 K/min) |
| Gases |
|---|
| Response time [s] | 1…10 |
| Software / programming |
|---|
| Adjustment of the switch point | pushbutton |
| Interfaces |
|---|
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor: Process Data Variable; Device Identification |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 2 |
| Process data binary | 2 |
| Min. process cycle time [ms] | 3 |
| Supported DeviceIDs | | Type of operation | DeviceID | | Default | 54 |
|
| Operating conditions |
|---|
| Ambient temperature [°C] | -25…80 |
| Storage temperature [°C] | -25…100 |
| Protection | IP 65; IP 67 |
| Mechanical data |
|---|
| Weight [g] | 248.5 |
| Dimensions [mm] | M18 x 1.5 |
| Thread designation | M18 x 1.5 |
| Materials | stainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); PC; PBT-GF20; EPDM/X |
| Materials (wetted parts) | stainless steel (1.4404 / 316L); O-ring: FKM 80 Shore A |
| Process connection | M18 x 1,5 internal thread |
| Displays / operating elements |
|---|
| Display | | function | 10 x LED, three-colour |
|
| Remarks |
|---|
| Pack quantity | 1 pcs. |
| Electrical connection |
|---|
| Connection | Connector: 1 x M12 |